Filter Results By:
Products
Applications
Manufacturers
Murray Loop
Use time domain reflectometry to locate signal loss or a Murray loop bridge.
- Pickering Interfaces Inc.
product
PXI Analog Output / Current Loop Simulators
These modules are aimed at simulating industrial control transceivers, utilizing 4–20mA current loops. The modules include built-in relays for shorts and opens functionality enabling fault insertion testing on every channel and also enable slew rates to be programmed so that different sensors can be effectively mimicked.
-
product
Loop A Line
TX916
The Loop a Line has been a Telstra standard for 20 years. It is probably the simplest time saving device available for contractors and technicians. Once fitted to the far end of a line you can switch between Open, Short, Connect, 600 ohm, and Tone modes allowing all installation and fault location to be performed from the one end without having to go back and forward from one end of the line to the other.
-
product
Antenna, Loop
EM-6871 | 30 Hz – 1 MHz
The EM-6871 Antenna can be used with any 50 ohm /Receiver/Field Strength Meter to obtain magnetic field measurements from 30 Hz to 1 MHz.
-
product
Antenna, Active Loop
EM-6876 | 9 KHz – 30 MHz
The Electro-Metrics EM-6876 Active Loop Antenna is used with EMI Receivers and Spectrum Analyzers with 50 ohm input and covers the frequency range of 9 kHz to 30 MHz.
-
product
Recorder for non-stop(Loop)
You just set the desired number of the days to keep track of, and Stream MultiRec will record them uninterruptedly 24 hours a day with no human intervention. The number of tracked channels is defined by the user depending on specific requirements and the storage capacity of the video server in use.
-
product
Single Loop Controller
1460
he 1460 has been designed to provide immediate visibility to the operator. At a glance, the programmable displays will show you the measured variable, the set point and the parameter being edited, the number of cycles or time remaining, the recipe name and number and also whether the cycle is in a ramp or soak mode
-
product
Loop Calibrator
MS-420
The Loop Calibrator is a multi-purpose process loop tool that offers high accuracy in an ultra-small, rugged package. A single pushbutton selects one of five current outputs (4, 8, 12, 16 or 20 mA), which can drive up to 300 Ohms, or can act as a 2-wire simulator with an external loop power supply of up to 30 VDC.
-
product
Active Dual Loop Antenna
KH30936
Beijing KeHuan Century EMC Technology Co,.LTD
KH30936 active dual loop antenna is used for adjusting, testing, measuring and other receivers. It has many advantages:1. The antenna coverage frequency is wide: 150KHz ~ 30MHz .2. The field strength value is measured according to the correction coefficient within the effective frequency range, which is convenient to use.3. The antenna power is supplied by the host, which is convenient for outdoor measurement.4. Compared with the single loop antenna, the advantage is to read the maximum value directly, which eliminates the tedious steps of rotating the antenna to find the maximum value and the interference of the human body to the signal.
-
product
3-Dimensional Loop Antenna Van Veen
Loop Antenna System ( LAS )3-dimensional large loop antennadiam. 2 macc. EN 55015 / CISPR 15
-
product
Current Loop Calibrator
LC-100
The Current Loop Calibrator an accuracy of 0.015% and a 0.001 mA resolution. The loop calibrator can simulate, power, and measure two-wire transmitters. With automatic Step and Ramp functions, the precision loop calibrator also enables remote calibration of 4-20mA devices.
-
product
Loop / PFC Testers
PeakTech Prüf- und Messtechnik GmbH
The PeakTech 2715 is a loop tester which is used to test the safety of electrical systems. These device measures the impedance of the short-circuit loop between the outer conductors of a circuit, whereby the probable short-circuit current is calculated. The protection of the circuit (miniature circuit breaker) must therefore trigger at a lower current than the expected short-circuit current, in order to avoid excessive heating of the lines and thus a fire risk. The PeakTech 2715 is due to its function and its robust design almost indispensable when performing new installations, but also for general checking of electrical systems, this device is the ideal companion.
-
product
Loop Meter
MZC-310S
The MZC-310S is a professional portable meter for testing electrical installations with over-current circuit breakers. The instrument measures short-circuit L-PE, L-N and L-L loop and prospective short-circuit loop current. A measurements can be done either with low testing current (up to 42A) with 2-pole method or high testing current (up to 280A) with 4-pole method that enables measurements with very high accuracy and resolution.
-
product
mA Loop Calibrators
Loop Calibrators are indispensable tools for process calibration professionals and we have just one you need. Choose from three different models depending on your need for accuracy and intrinsic safety. Each one is feature-rich and simple to operate and read.
-
product
Loop Calibrator
Model KM CAL-904-MK1
Kusam Electrical Industries Limited
• 4-20mA (1kΩ Load, 24V Loop Output).• 0-20mA and 0-24mA output ranges.• 0.025% Basic Accuracy.• Auto Ramp and Step functions.• 0-100% output with percentage step option.• 0-24V DC voltage source.• Open loop and overload buzzer alarm.• Low battery indication.• Simple Operation Interface• Warning beeper when output is open• Pollution Degree 2.• Ambient temperature 0~40℃.• Power Consumption 150mA at 24V 1kΩ load
-
product
Antenna, Loop Sensor
EM-6873 | 20 Hz – 100 KHz
The EM-6873 Loop Sensor Antenna uses passive circuits to transform magnetic field components between 20 Hz – 100 kHz to an equivalent open circuit two-terminal voltage on the receiving instrument. Use of the conversion Factor Chart, supplied with each antenna, will yield the strength of the magnetic induction field referenced to a uniform field. The loop is electrostatically shielded and therefore is sensitive only to the magnetic component (B-field) of the electromagnetic fields.
-
product
IntelliPoint RF - Loop Powered Level Switch
The IntelliPoint Loop Powered Two Wire provides a capacitance probe level switch with current output and “On-Board” self-diagnostics to ensure reliability and level sensing elements for a wide variety of temperatures, pressures, and materials.
-
product
Hysteresis Loop Tracer
MESA
The MESA is the only hysteresis loop tracer on the market that can make measurements in the frequency range of 10 Hz and below. Competing units operate with more-easily generated 60 Hz drive fields, and can have errors of as much as 30% in coercivity (Hc) measurements.
-
product
Floating Power FET moduleAmp Loop
PFM1010
The PFM1010 Module is a precision instrument capable of measuring all common DC parameters in a power MosFet as well as many of the AC parameters. This module uses some very innovative techniques to make it possible to measure parameters like Rdson down into the sub-million-ohm range.
-
product
Closed Loop Hall Effect Current Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor
-
product
Loop and Detector Testers
HILT Kit
The HILT-Kit is easy to use, with quick and accurate tools designed to test and measure the parameters of inductive loops used in the Traffic Signal, Vehicle Data Collection, and Parking industries. The test kit is housed in an impact resistant case with a set of 6 foot test leads and adapters. The sturdy, injection molded plastic carrying case is custom designed to hold the HILT-9000 and its accessories, as well as the LF-22 Loop Finder and AEMC 6527 Digital Megohmmeter for a complete loop analysis kit. (The HILT can be ordered by itself, without the Loop Finder and Megohmeter as the HILT-9000)
-
product
Resistance Tester With Leakage Current (Loop Current)
GT00WD00ZY
*screen display*Double protection insulation*Non-contact measured resistance, safe, fast
-
product
- RS-232 to Current Loop Converter
Model 65A
FEATURES: Active/Passive Loops; 20 or 60 mA. Operation; DC To 19.2 KBPS; Half/Full Duplex; Optically Isolated; DTE/DCE Selectable. The Model 65A is a small, versatile, RS-232 to Current Loop Converters for use with teletypes or computers providing local terminal input via a 20mA. (or 60 ma.) current loop. The Model 65 includes a wall mounted transformer and internal power supply circuitry.
-
product
mA Loop Calibrators
AMETEK Sensors, Test & Calibration
Our mA loop calibrator is an economical and easy-to-use calibration device for sourcing and measuring mA signals. Measure and source current to 24 mA and measure voltage to 45 VDC. Combine our 24VDCPS with one of our handheld pressure calibrators to calibrate transmitters in the field.
-
product
Loop Calibrator
6500 LC
Standard Electric Works Co., Ltd
● 4-20mA (1kΩ load, 24V Loop Supply).● 0.025% Basic Accuracy.● Simple Operation Interface.● Auto Ramp and Step Functions.● 0-20mA, 0-24mA selectable.● Incremental percentage setting : 0-100%.● Warning beeper when output is open.● 0-24V output.● The minimum load of 20kΩ on voltage mode.
-
product
Micro-Ohmmeter and Loop Resistance Tester
LRT 6000
LRT 6000: The right solution for impedance resistance measurement in compliance with all aircraft specifications on plane, helicopter, rocket, army vehicles for both production andmaintenance. It is a very easy-to-use and versatile instrument. Its ergonomics allow the user to use it either placed on the ground or across one's shoulder or chest. Awide back-lit LCDdisplay combinedwith an intuitive keyboard ensures simple and easy operation.
-
product
Modular Breakout System for Hardware-In-Loop Simulation
Designed in partnership with OPAL-RT Technologies, this Modular Breakout System combines a BoB feature set with the added flexibility of an FIU. By mating the FIU chassis directly to the BoB using our plug-in modules, cabling is minimized, creating a more compact reliable design and improving signal integrity.
-
product
Saicheng Adhesive Loop Tack Tester
VOC-01 Loop Tack Tester is applicable to measure the tack property of adhesive tapes, pressure-sensitive adhesives (PSA), and adhesive materials according to ASTM D6195.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 4 Channel
43-765-004
The 41/43-765-004 is an 4-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
PXI Analog Output/Current Loop Simulator Module - 8 Channel
41-765-003
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilizing current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signaling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Loop Antenna
ZHX7-0.009-200-1486
Loop Antenna, Frequency 0.009~200MHz, Linear Polarization, N-Female
-
product
Loop and Line Powered Level Switch
Safety IntelliPoint
The Safety IntelliPoint level switch provides a capacitance probe level switch with either a current output or relay contacts and “On-Board” self-diagnostics to ensure reliability. This SIL Intellipoint conforms to SIL 2 specifications providing the ultimate in level switch integrity and level sensing elements for a wide variety of temperatures, pressures, and materials.