Filter Results By:
Products
Applications
Manufacturers
Load Banks
Test a power source by providing controlled amounts of load to create conditions found in thier application.
See Also: AC Load Banks, DC Load Banks, Inductive Load Banks, Reactive Load Banks, Resistive Load Banks
- Pickering Interfaces Inc.
product
PXI 20 Banks 0f 4 Channel 1 Pole MUX
40-615-021-20/4/1
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
product
Stationary Load Banks
Polaris
The Polaris Load Bank is a completely self-contained, freestanding unit which includes all resistive load elements, load control devices, load element branch circuit fuse protection, main load bus and terminals, cooling system, control power supply, unit controller and malfunction detection system and NEMA type enclosure.
-
product
DC Resistive Load Banks
LB-Series
Eagle Eye offers multiple DC Load Banks ranging from 10 480 VDC at 1 amp or 5 amp Resolution. These load banks offer a simplistic solution to UPS Battery Load Testing. Each load bank is easy-to-use with an LCD display operator control panel and user-friendly fan switches, load step switches, and master load switches. UPS load testing stimulates a real-world performance demand of a critical power
-
product
Load Banks
BD Series
*12 kW, 15kW and 18kW Battery Discharge Load DC*All of our Load Banks are continuously rated for Power and Current.
-
product
Portable Load Bank
Atlas-Megawatt
The Atlas-Megawatt provides 1000KW of resistive load at both 240V and 480V, 3-phase. It can be applied at any AC voltage to 480VAC, 50-60-400 Hertz, single or 3-phase. Load step resolution is 5KW.
-
product
Resistive Load Banks
R Series
Load banks are devices which contain resistive, inductive and/or capacitive loads, apply the load to an electrical power source and dissipate the power of the electrical source. Portable and stationary resistive load banks incorporate as low as 1 kW load step increments for testing small to large generating sets. The fine control resolution ensures accurate load control and power factor targeting adjustments.
-
product
Load Banks
EL Series
*12kW, 15kW and 18kW DC Electronic Load*All of our Load Banks are continuously rated for Power and Current.
-
product
Load Bank
Titan
Very high capacity electrical loads, typically in excess of 10MW, for testing, maintenance and performance analysis of large AC power systems can be formed using the Simplex Titan Load Bank as a building block element. The Titan Load Bank is a self-contained, semi-portable unit providing resistive and inductive loads to 15KVA, .8 power factor, to 600VAC.
-
product
Load Bank
Neptune
The Neptune Load Bank is a completely self-contained, freestanding unit which includes all resistive load elements, load control devices, load element branch circuit fuse protection, main load bus and terminals, cooling system, control power supply, unit controller and malfunction detection system and NEMA type enclosure.
-
product
Dc Load Bank
Highly reliable and durable new alloy resistor is used for the JUNXY DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.
-
product
PXI 36 Channel Data Comms MUX, 96-pin SCSI
40-735-912
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
Load Bank
Being the reckoned names in the industry, we offer world-class range of Load Bank that is manufactured with perfection. We offer in different configurations such as Resistive, Inductive, and Capacitive. Our entire product range has high compressive strength and ensures smooth operations. They are durable in nature and are delivered in stipulated time frame.
-
product
AC Load Banks
X250S Series
Mosebach Manufacturing Company
The X250S is the only one of its kind: 250 kW in a very small package. Light, portable; with digital meter and recording capability. Center lifting bar and casters are both available as options. Ideal for "Black Tests" in data centers as blowers are powered externally with 120VAC
-
product
Automatic Power Factor Controller
Power factor controlling based on the capacitor bank switching historyCapacitor is automatically disabled when it is deteriorated beyond a certain levelAutomatically learns the number of capacitors connected and the value.Capacitance-based power factor correction takes care of variation in voltage and frequency.Controlling based on VAR parameter and availability of built-in alarms Flexibility for site programmability of CT ratio suitable for any load
-
product
Battery Testing System
C8000
The Cadex C8000 stands in a class by itself in flexibility and affordable price. Test SMBus batteries, monitor cell balance and capture load signatures to observe batteries with a unique load protocol. Add a thermal chamber, an external load bank, a safety circuit and alarm to form a command center and you begin realizing the unique qualities of this fine battery testing system.
-
product
Battery Data Logger
BDL-3926C
Kongter Test & Measurement Co., Limited
BDL-3926C Battery Data Logger is wireless monitoring device for string voltage, cell voltage, current and temperature. It works individually to reflect battery status or co-works with Kongter’s other battery test equipments like battery charger and K-3980 DC load bank. For different battery systems, it has customized configuration from 12V to 480V or upper. And it has easy expansion for all battery systems.
-
product
AC Load Bank (Resistive)
K-1000 Resisitive
Kongter Test & Measurement Co., Limited
The kW of a resistive load bank is “real” power in electrical terms. When a resistive AC load bank is used to test an engine generator set the engine will produce its full horsepower rating, dissipate engine exhaust gases, and produce thermal energy into the engine cooling system. The resistive load bank in fact, will completely test the engine and its various systems.
-
product
Capacitive Bank Load
Supreme Instrument Laboratories
Capacitive Bank Load Three phase suitable for operation on 415/440 volts three phase AC 50Hz housed in well ventilated sheet steel cabinet with bakelite front panel, complete with indicating lamps, voltmeter to indicate the input voltage and Ammeters to indicate, the load. ON/OFF switch, discharge switch etc. available in continuously variable type.
-
product
5KVA to 100KVA Industrial UPS (3Ø – 1Ø)
NSP Series 5KVA to 100KVA
- Designed for powering critical Industrial and IT systems- DSP controlled IGBT based PWM technology- Design topology enables N+1 parallel redundancy- Industrial grade high speed CAN bus communication- User Friendly Matrix LCD and LED mimic front control and digital monitoring- Fully rated make before break maintenance bypass operation- Optional break-less load transfer via static switch- Low harmonic distortion- High crest factor tolerance and dynamic stability- Lower TCO- Continuous full rated power at ambient as high as 45°C- N+1 Parallel operation of UPS without any common hardware- Advanced Communication Capability (RS485/Modbus/SNMP)- High branch fuse clearing capacity- On-line battery bank test without load disconnection- Compact, elegant, and light weight enclosure- Easy installation with wheels for maneuverability and front bottom terminals
-
product
XR Resistive Reactive Load Banks
Mosebach Manufacturing Company
Mosebach’s XR series load bank offers you a range of options for resistive reactive loads in both lower voltages of 480 and 600 or MV at 4160 and higher. Outdoor rated user friendly for years of use.
-
product
AC Load Bank (Resistive & Inductive)
K-1000 Resistive & Inductive
Kongter Test & Measurement Co., Limited
Kongter resistive & inductive AC load banks are used to simulate the motor loads or other electromagnetic devices working at their rated power factor. Many backup generators and turbines are rated at 0.7, 0.8 or 0.85 power factor and need to be commissioned at nameplate capacity using a combination of resistive and reactive load to fully qualify their operating capability. Using a resistive & reactive load bank enables comprehensive testing from a single unit.
-
product
PXI Single 36 Channel MUX, SMB Connectors
40-735-912-S4
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
product
AC Load Banks
XL2000-XL3000 Series
Mosebach Manufacturing Company
The XL2000-XL3000 Series is a group of outdoor rated load banks ranging from 2000 kW to 3000 kW. These load banks range in features from permanently mounted with direct bus bar connections to trailer mounted and easy disconnect cam lock connections. Mosebach can also integrate a wide variety of control systems into the load bank to meet your needs.
-
product
Generator Loading System
Mosebach Manufacturing Company
GLS (Generator Loading System) is a load bank for use with your generator to load it automatically to your set point. This will keep your generator running at its optimal point and reduce your maintenance costs. Fully programmable by you.
-
product
AC Load Banks
XL1000-XL1250 Series
Mosebach Manufacturing Company
The XL1000-XL1250 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
product
Battery Monitoring System
BMS-3923
Kongter Test & Measurement Co., Limited
This battery monitoring system is an innovative solution to measure battery condition with communication way of Power Line Carrier (PLC). With multi-frequency measurement, users can monitor and analyze battery in all aspects: internal resistance, voltage, current, capacitance, temperature and so on.Based on our years experience for battery management system, we build very mature mathematical model that precisely predicts battery capacity. This will in another hand reduce the time that we spend on capacity measurement using a battery load bank.
-
product
LB-Series Digital AC Load Banks
The LB-Series AC Load Banks are designed for high power portable load testing of generators, UPS, and other critical AC power sources. Available models meet a range of voltages including but not limited to 208, 380, 440, and 480 VAC. Load power model options reach 1000 kW standard with other options available.
-
product
Custom Load Banks
Power House Manufacturing, Inc.
Custom Load Banks are our specialty. Power House Manufacturing is dedicated to providing our customers with exactly what they need. Having years of custom load bank manufacturing experience, Power House can deliver the perfect custom testing solution you require.
-
product
AC Load Bank
AC-LB-Series
Eagle Eye AC Load Banks are commonly used for testing generator sets, UPS units, aircraft power inverters and other government and military AC power sources. The Eagle Eye AC LB-Series is the smallest in the industry and offers unmatched durability in even the harshest testing environments. Eagle Eye offers several standard models as well as custom AC Load Banks.
-
product
PXI Dual 18 Channel MUX, 96-Pin SCSI Connector
40-735-912-S1
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.