Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe High Density Matrix Module, 128x2, 1-Pole, 2A, 60W
42-584A-001
Our model 40-584A, along with the following models 40-585A, 40-586B and 40-587A are high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. This module is also available in PXIe format (42-584A-001).
-
product
Standard- 27.20 (771.00) - 64.00 (1814.00) Godzilla High Current Probe
HC375F-4
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
product
High Insulation Digital Clamp Tester
HCL-5000KN+
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Wide AC current measurements for 0.01A~500A.・Easy operation, Push to Open and Pull to Disconnect Mechanism.・Safe AC current measurements for high voltage circuit (AC80 to 7000V).・Auto power off function and Splash proof structure.
-
product
Current Transformer Pin Type
PCT 1
Shanghai Powoo Industry Develop Group Limited
- completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - the secondary lead wire is pin format, which can be directly welded on a PCB; - the primary lead wire could be pin, soft wire as well as tin-plated copper-core wire; - linear output current, high precision; - small volume, light weight, easy for installation; - encapsulated with epoxy resin to ensure strong insulation ability; - ABS anti-combustion plastic casing.
-
product
Current Protection Relay
The main earth fault protection relays in distributions systems, power stations & large manufacturing / processing plants can fail to detect a high impedance break down to earth causing hazard to human life & potential damage to plant & equipment. In these & other situations demanding extra sensitive earth fault protection, using solid state techniques, can be applied to detect earth currents down to 0.5% of the CT nominal current.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
product
Human Potential Measuring Instrument
KSD-4000 / KSD-4100
Electronic devices and metal tools carried by workers have individual capacitance to ground and are charged at human potential. When the charged electronic device touches the ground or a metal tool touches the electronic device, a transient current with a high peak current flows at high speed, Causing A Failure. By Using The Human Body Potential Measuring Device, The Potential Of The Human Body Can Be Measured Accurately, And It Can Be Immediately Determined Whether Or Not The Electronic Device Is Damaged By The Potential. You Can Also Find Out How Much Static. .. .electronic meters such as conductive floors, electrostatic mats, electrostatic shoes, and wrist straps reduce the human potential.
-
product
PXI Monitored Multiplexer, Quad 32-Channel, 1-Pole
40-619-204
The 40-619-204 is a high density PXI 2 A multiplexer module in quad 32-channel configuration using high quality electro-mechanical signal relays allowing each channel to switch current up to 2 A and voltage up to 250 VAC/DC.
-
product
High AC Current Capacitor
LC1/LC2/LC3-RNM
Induction Heating Processing Equipment, Electric Current Welding, High Power Resonant Circuits, Motor Controls; Oscillating, Bypass, Coupling circuits, High AC Current applications, High-Frequency AC Filter and Medium Frequency Power applications.
-
product
Programmable Linear DC Power Supply, 3 Output, 0-32V/0-3.2A, 2.5V/3.3V/5V/3.2A
T3PS3000
Teledyne Test Tools new T3PS3000 is a Linear Programmable DC Power Supply with a 4.3 inch TFT LCD display. It has three isolated outputs: two adjustable channels and one selectable channel from 2.5 V, 3.3 V, and 5 V with output short and overload protection for each channel. Support for series and parallel operation of the two main channels extends its flexibility beyond the standard specification. The T3PS3000 features include programmability via USB or LAN, a graphical display of power waveforms, and the high resolution numeric display of voltage and current. Typical users are Education, Production, and Design and Development.
-
product
PXI Mixed Configuration Relay Module - 12 Cells Populated
40-138-AA-BB-CC-DD (12 CELL)
The 40-138 2A Relay Module with 12 cells populated is a cell-based mixed configuration switching module suitable for applications requiring medium power switching with high density. It provides a broad selection of mixed relay types for greater flexibility and features 2A current capacity and voltages to 300VDC/250VAC.
-
product
High Frequency Current Transformer
HFCT
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.
-
product
High Accuracy (0.045%) Precision Multi-Channel Harmonic Power Analyzer
PA910
The PA910 power analyzers offer expanded power analysis options. The PA910 offers ultra high 0.045% power accuracy for all channels and improved voltage and current self-heating adders over those of other power analyzers. In addition, the PA910 provides easy channel selection for the user while offering 100 full precision readings per second and measurement bandwidths sufficient to handle 5 MHz waveforms.
-
product
PXI Solid State Multiplexer Module, Single 6-Channel, 10 A
40-666B-012
The 40-666B-012 is a single 6-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.
-
product
Primary Current Injection Testing
KAM
This substation testing device is designed to grant high current output when needed in substation commissioning activities.
-
product
Digital Panel Meter
VAM
Chuan Sheng Electronics Co., Ltd.
VAM Voltage & Current Meter has been designed with high accuracy dual channels(isolated) measurement, dual display and communication of 0~600V and 0~10A for DC/AC/TMRS. In compact size(48 x 96mm)● Build in mathematic function such as Addition / Subtraction / Multiplication / Division / high or low selector in 2 channels input to meet various testing equipment inquiry.They are also build in 4 Relay outputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of industrial applications.
-
product
PXI 40Amp 14Volt 2xSPST Automotive Relay
40-180-001
Models 40-180/181 are High Power Relay Modules available with 2 SPST, 4 SPST or 2 SPDT contacts. They are capable of switching inductive/capacitive loads up to 40A at 14VDC or 20A at 28VDCThe 40-180/181 High Power Relay Modules are suitable for switching heavy loads or for slaving large external relays, contactors and solenoids. In particular these relay modules are designed for automotive test applications requiring the switching of D.C. voltage at high current. The 28V version is suitable for truck system test applications.
-
product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1Z-10
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Leaking Current Meter
7610B
Peaceful Thriving Enterprise Co Ltd
This is a stable, low power consumption, and high accuracy 3 1/2 digits (2000 counts) leaking current tester for automobile. Leaking current for automobile is generally as small as milliamps, which is hard to measure by clamp meter. By plug this meter with the fuse box, user is able to measure leaking current as small as 1 mA.
-
product
PXI 2A Multiplexer, 1-Bank, 16-Channel, 8-Pole
40-614C-018
This 1-bank, 16-channel, 8 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
PXI 2A Multiplexer, 8-Bank, 4-Channel, 4-Pole
40-614C-005
This 8-bank, 4-channel, 4 pole version is part of the 40-614C High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-1T30-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Ultra High 1.16 (33.00) - 9.70 (275.00) Long Travel Bead Probe
BPLT-25HF-9.7
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
product
Single 48-Channel 1-Pole 5 Amp PXI Solid State Multiplexer
40-652-001
The 40-652 range of multiplexers uses solid state relays with high tolerance to surge currents and hot switching events. Each multiplexer provides an isolation relay in the common to minimize capacitive loading when expanding the multiplexer across multiple modules. The 40-652 can sustain 30A for 300s on hot or cold switching. User connections are made via a 50-way D-Type connector which is fully support by our comprehensive range of cables and connector accessories.
-
product
PCI 2 Amp Multiplexer, Single 4-Channel, 8-Pole
50-635A-104
The 50-635A-104 is a single 4-channel, 8-pole MUX and is part of a range of PCI Multiplexer cards available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
product
40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger
SD750100G
Zhejiang Sandi Electric Co., Ltd
40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%
-
product
Analogue (1kV below) Insulation Tester
2732 IN
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on "low ohms" : 3Ω & 500Ω.● Compact and lightweight.● AC voltmeter with linear scale up to 600 Vac.● 200mA continuity short circuit current.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display or external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Designed for meet international standards.● Supplied with high quality test leads.● BS 16 edition.
-
product
Monitoring Solar Panel Strings, DC 30A, Φ10mm
CTF-60-10DC
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Compact, Space-saving, Low Cost DC Current Sensors.・Split-core type, easy to apply to existing circuit.・Easy to use by unipolar +5V power supply.・High speed responsibility – less than 10μsec. 0 rated primary current.・Suitable for monitoring solar panel strings.
-
product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-1L-2
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Primary Test Equipment
LET-400-RD
It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.
-
product
Alternate 0.99 (28.00) - 6.00 (170.00) Long Travel Bead Probe
BPLT-25HF-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm