product
PXI 10A Fault Insertion Switch 6-chan 2-bus
40-192-012
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
product
PXI BRIC8 FIBO Matrix Dual 120x4 3pin brkout
40-592A-106
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
NI CAN No Termination Cable w/Power Terminals, HS/FD/LS, 2m
782578-02
9-Pin Female D-SUB With 2-Pin Female Power Screw Terminal to 9-Pin Female D-SUB CAN Cable - The DB9F-PT2F-DB9F CAN Cable, sometimes referred to as CAN Cable (with power terminals), connects C Series CAN Interface Modules, C Series LIN Interface Modules, or C Series Multiprotocol Interface Modules that have ports requiring external power with external CAN signals. The screw terminals on the cable allow for the direct wiring of power and ground to the port on the CAN interface. This cable is compatible with high-speed, flexible data-rate, and low-speed/fault tolerant CAN signals and is available with or without termination.
-
product
CT Admittance Tester
505B
Red Phase Instruments Australia Pty Ltd.
Field testing kWh meters is easy, field testing CTs when live is much more difficult. Our admittance tester can test CTs live with 50Hz or 60Hz current in the metering circuit. This technique does not confirm the accuracy of a CT but it will detect faults that give metering errors, such as shorted turns, metering circuits shorted to ground and tampering of CTs. CT faults can cause large revenue losses. Admittance testing only adds 10 minutes to a routine polyphase meter test, giving cheap insurance.
-
product
5mA High Accuracy Ground Fault Detector
HA-GFD
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
product
Ground-Fault Detectors for Ungrounded Systems
Early detection of ground faults on ungrounded systems allows critical systems to remain online while faults are identified and resolved. By continuously monitoring the system's insulation resistance, Bender's ground-fault detectors can provide early indication of both immediate and trending ground faults before leakage current may be of concern.
-
product
Handheld PD Tester
Weshine Electric Manufacturing Co., Ltd
TEV partial discharge inspection instrument uses two emerging technologies, transient-to-ground voltage (TEV) measurement and ultrasonic (US) measurement, to detect faults in switchgear. The equipment is portable and easy to operate. The TEV sensor is attached to the wall of the box, and the US sensor scans and detects along the gap on the switch cabinet.
-
product
Mobile Cable Fault Location System
BAUR Syscompact 4000
BAUR Prüf- und Messtechnik GmbH
Fault location with Syscompact 4000. The Syscompact 4000 is a compact, fully enclosed fault location system for pre-location and pinpointing of high-resistive, low-resistive and intermittent faults on low- and medium-voltage cables. Easy operation and the use of latest fault location methods enable fast and safe fault location.* Location of low-resistive, high-resistive and intermittent cable faults* Efficient cable fault pre-location methods* Pinpointing according to the noise location method or acoustic propagation time measurement* (with Universal Locator and ground microphone)* Sheath fault location according to the step voltage method (with Universal Locator and two measurement probes)* Easy to handle
-
product
Hall Effect Sensors
A new range of sensors based on closed loop hall effect technology, for measuring and monitoring of e.g. secondary transformer overload or shortcircuit detection, DC link from ground fault and overload, motor overload.
-
product
Ground Fault Locator
DC Trace
SCOPE introduces DC Trace, the most advanced and user friendly DC Earth (Ground) Fault Locator. This portable instrument consisting of Signal Generator & Signal Receiver (DC TraceR) uses latest digital signal processing technology. It’s ability to detect earth faults in live DC system quickly & accurately in online condition greatly relieves the substation maintenance engineers from nightmare of earth leakages & it’s detection.
-
product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 4 Channel
50-201-004
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, Broad R-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Field Ground Module
SEL-2664
Schweitzer Engineering Laboratories, Inc.
Add the SEL-2664 Field Ground Module to the SEL-300G or SEL-700G to protect all the critical components in your generator with one comprehensive relay. Or, add the SEL-2664 to the SEL-2664S to complete ground fault protection on both the rotor and stator.
-
product
Ground Fault Locator
K-3837
Kongter Test & Measurement Co., Limited
Kongter’s K-3837 Ground Fault Locator is developed to fast detect, trace and pinpoint virtual grounding faults on LIVE DC systems with earth fault. It will save you from long time unnecessary troubleshooting and helps to increase the stability of your electrical equipments. It is widely used in various DC systems including power utilities, locomotive, telecom and etc.
-
product
PXI BRIC4 FIBO Matrix Dual 155x4 2pin brkout
40-592A-115
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
Ground Fault Finder
FST-JD200 DC
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1. The high-precision sampling clamp meter The device uses a high resolution (0.1mA) signal sampling direct current clamp meter that can achieve multi-point grounding and high resistance ground point positioning...
-
product
Service Drop Locator
VM-560
The VM-560 is a general-purpose locator used to detect buried pipe and cable services in a variety of situations. With a 50/60Hz passive power locating frequency and three active frequencies, the VM-560 locator will meet the requirements of those wishing to detect the presence of active power cables and to trace short ranges. The VM-560 transmitter also has the additional frequency of 8kHz Fault-find so it can be used to detect the presence of ground to sheath faults on cable when used with the VM-510 Stand Alone A-Frame fault locator.
-
product
DC Ground Fault Finder
FST-JD200
Foresight Electronics Co., Ltd.
FST-JD200 not only can provide a solution on accurately testing the faults of the indirect-grounding of the direct current system, non-metal grounding, loop grounding, simultaneous grounding of the anode and cathode, balanced grounding of the anode and cathode and multi-point grounding 1.
-
product
Socket Tester
1945
Peaceful Thriving Enterprise Co Ltd
This is a portable 220VAC socket tester to inspect the wiring conditions. The tester also features current variation for simulation of different leaking current. With the current variation, technician is able to test the condition of Ground Fault Circuit Interrupter (GFCI) / Residual Current Device (RCD) easily.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
AC Current Transformers
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers. Various outputs include 5 amp secondary, high turns ratio voltage outputs for both wire leads and pcb configurations. Our products are UL Recognized for both US and Canada.
-
product
Under Ground Cable Fault Locator
Widely used in electrical and power generation sector for testing underground cables in order to detect any fault.
-
product
NI CAN No Termination Cable w/Power Terminals, HS/FD/LS, 1m
782578-01
9-Pin Female D-SUB With 2-Pin Female Power Screw Terminal to 9-Pin Female D-SUB CAN Cable - The DB9F-PT2F-DB9F CAN Cable, sometimes referred to as CAN Cable (with power terminals), connects C Series CAN Interface Modules, C Series LIN Interface Modules, or C Series Multiprotoco Interface Modules that have ports requiring external power with external CAN signals. The screw terminals on the cable allow for the direct wiring of power and ground to the port on the CAN interface. This cable is compatible with high-speed, flexible data-rate, and low-speed/fault tolerant CAN signals and is available with or without termination.
-
product
Trailer Light Testers
Pro-Check 725
Pro-Check trailer light testers with advanced electrical diagnostics are rugged, lightweight, and economical. They independently test each electrical circuit on a trailer to ensure proper connectivity. The Pro-Check identifies each specific type of electrical wiring fault. Lite-Check’s patented active diagnostic system takes the guesswork out of identifying trailer light and electrical problems. The Pro-Check commercial trailer light tester with electrical circuit diagnostics, not only identifies faults, but the specific circuit the fault is on. Faults are identified as “Open Circuit”, “Open Ground”, “Short” (w/all circuits identified), or “Chassis Ground”. Audible alarms alert technicians to found electrical faults.
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
PXI BRIC4 FIBO Matrix Dual 20x4 3pin brkout
40-592A-001
The 40-592A FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short circuits to ground or battery, or short-circuits between input/output lines.
-
product
Voltman True RMS Industrial Safety Voltmeter
125
If you need a continuity function or harmonics are a problem then the Voltman TRMS is for you. Non sinusoidal waveforms from variable speed motors cause problems for most meters but the Voltman TRMS meter is specifically designed to produce accurate and dependable readings of distorted waveforms. When there is no voltage present the unit automatically tests for continuity, ground faults or shorts.
-
product
Surge Voltage Generator
SSG 1100
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit
-
product
PXI BRIC8 HD FIBO Matrix 186x8 2pin brkout
40-592-121-186X8-2P
The 40-592 FIBO (Fault Insertion Break-Out) Matrix Module is a large-scale high density switching matrix based on the Pickering BRIC™ format. The fault insertion BRICs are designed for applications requiring the simulation of a variety of faults in complex, high pin count, applications involving sensors and control units. Typical faults that can be simulated are open-circuits, short-circuits to ground or battery, or short-circuits between input/output lines.