measures insulation, excitation current, turns ratio, winding polarity saturation and/or winding resistance. Current Transformers
See Also: Transformer Test, Transformer Testers, Current Transformer Test Set
- Valhalla Scientific Inc.
product
KVS Rugged Igniter Tester With Current Monitor
4314
The Valhalla Scientific Model 4314 KVS Digital Igniter Tester is designed to provide extremely safe and reliable resistance testing of explosive or volatile devices. Proven uses include fuses, squibs, igniters, explosive bolts, automobile airbag initiators and many others.
-
product
Transformer Test Equipment
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
product
High Current Transformers
High Current Transformer is designed to elevate and check the temperature of the conductors at high current levels, in order to simulate the current loading conditions found in electrical circuits. High Current Transformer is designed as an open type transformer that uses the test object as its secondary coil or has 1 or 2-turn self secondary winding. The conductors cores' temperature depends on the short-circuit high current caused by the test object. According to the current going through the test object, the test temperature of the conductor will change. The loop temperature is measured by a thermocouple probe which is directly connected to conductor.
-
product
High-Voltage Test Device
PGK 260 HB
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK HB. There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit. *Testing of medium- and high-voltage cables * DC voltage testing of up to 260 kV output voltage with positive or negative polarity * AC voltage testing - up to 190 kV for switchgear, busbars and insulating elements * Easy-to-maintain 2-piece design
-
product
Primary Test Equipment
LET-400-RD
It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.
-
product
FTL Test Block
FTL testblock with dust cover and current disconnect pinThe FTL is a test block for interfacing substation devices (protection relays, fault recorders, revenue meters, ... ) to the voltage and current transformers and to other equipment on the system side of a power grid. The FTL test block uses disconnect pins to isolate the substation devices from the system side equipment. Once isolated, secondary injection can be performed using banana jacks on the front side of the test block.
-
product
High Frequency Current Transformer
HFCT Ø 140mm
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
product
Transformer Testing
The ART-3D series of Automatic Ratio Testers are precision instruments, designed to measure the turn ratios, phase displacements, excitation currents of single phase and three phase power, distribution and instrument transformers in conformity to the IEEE C57.12.90 & IEC 60076. Now featuring an enhanced test lead design, the ART-3D is the perfect instrument for real-life field usage. ART-3D series also has Anti Induction circuit which makes it suitable for system voltages upto 765KV.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
Oil Immersed Test Transformer
SG-YD
Wuhan Sangao Electrical Test Installations Limit Co.
AC and DC test oil immersed transformer.Traditional oil immersed test transformer is used to do power frequency withstand voltage and DC current withstand voltage test for variety kinds of high voltage electric device, insulating material.YD series oil transformer, also known as test booster, which test insulation strength under specified voltage for various electric products, components, insulation materials. It can test products insulation level, find insulation defect and judge overvoltage ability. It is widely used in power station, power supply and distribution system and research institute.
-
product
ANSI Metering Current Transformer Burden
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.
-
product
Current Transformer Test Set
Vanguard Instruments Company, Inc.
The EZCT-2000C is Vanguard’s third-generation microprocessor-based current transformer test set. Designed specifically for CT testing, the EZCT-2000C has the following outstanding features that can greatly increase productivity and save time during the commissioning stage:
-
product
10 A portable digital micro-ohmmeter
MPK-253
The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.
-
product
Automatic Voltage Regulating Relay- Standard Model
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
AC/DC Withstand Voltage Test
WB2671A/WB2671B
• Output voltage: 0-5kV (AC/DC); • Cutoff current range: AC 0~20mA (WB2671A)/0~100mA (WB2671B); DC 0-20mA; • Test time: 1-60s; • Transformer capacity: 750VA.
-
product
DC Current Bias Supply
DC1000A
To guarantee the quality and performance of inductive components such as inductors, chokes and transformers they are tested at their real-life operating point. If the inductor is designed to carry a DC current, then its inductance must be measured with that DC current present. Until now, these measurements were made by an LCR meter connected via special interfacing to a DC bias supply available only from the manufacturer of the LCR meter. The unique NEW DC1000A can be used with any precision LCR meter and connects simply into existing test fixturing.
-
product
Instrument Transformer
CT & PT Test Equipment
Measurements International Ltd.
Calibration of Voltage and Current Transformers from a Single Instrument, Calibration of Instrument Transformers with Different Rated Ratios Using One Single Reference Standard, Calibration of Voltage Transformers (VT) up to 800 kV When Used with MI 2500 Series of HV Dividers and Standard Capacitors, Calibration of Current Transformers (CT) Up to 10000 A When Used With MI 7020 and/or 7200 Series of Precision Current Transformers and/or Current Comparators, Test Frequency from 15 Hz to 100 Hz70.
-
product
Digital Electrical Network Analyzer
1826 NA
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Measures Earth Resistance without the need for poles in the ground or external measuring wires.● Earth measurement uses the real earth current path and the current generated by the electric network, without the need for any disconnection.● The Earth Resistance displayed is exactly the earth resistance that the earth current will need to go through if an earth fault occurs. No need to add all the bonding points and connection paths resistances.● Displays voltage supply at the transformer (Line to Neutral), without loading the transformer. Displays voltage between Line (Phase) and Earth (Ground), without drawing any current.● Measures the impedance of the line itself so you can analyze and differentiate between the multiples paths of the wiring.● Measures the Neutral Impedance. Single one smart push button operation; ON, Test, Scroll trough results and menus.● Checks wiring integrity (LEDs).● Auto off/auto ranging (software ranging). ● Combined prospective short circuit current, loop, individual wire and Earth Tester.● Voltage test L-N and L-E.● Loop test for L-E and L-N and PSC.● Enables analysis of constituent components in L-E and L-N loops giving resistance of earth, neutral wire, live wire and transformer winding.● Display can be customized for large orders.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
Test Set For Instrument Transformer
This modern Test Set For Instrument Transformer is used for measuring relative errors of Instrument Voltage and Current Transformers. This is developed for reading out the unbalance of any bridge circuit. It also calculates the burden associated to the test sample. In addition to this, it further converts it to ratio and phase error values for presenting them on a LCD screen. With high-tech microprocessor controller, it ensures to provide quick and correct measurements.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Loading Rheostats (Resistive Load)
Supreme Instrument Laboratories
Loading Rheostat is a device specially designed to meet the requirements of Engineering Laboratories, Electrical Test Rooms and Industries. It is used for loading transformers, power generators, supply mains etc. neatly and efficiently. It can also be used advantageously for regulating current and adjusting voltage besides its application for calibrating meters and thus eliminating the need for graded rheostats.
-
product
Transformer Demagnetization Tester
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
product
Megohmmeter Insulation Tester
AMIC-30
The AMIC-30 insulation tester is a small portable meter designed to measure insulation resistance in electrical and telecommunications installations, cables, motors, transformers and other equipment. The test voltage can be programmed in steps from 10 V to 1000 V. The instrument can measure both insulation resistance over a wide range (0,1kΩ...100GΩ), and insulation leakage current, capacitance and other parameters. All test results can be stored in the internal memory and sent to a computer via the included wireless USB receiver. The meters are supplied with rechargeable Ni-Cd batteries.
-
product
Digital ESU Analyzer
ESU-2050P
Calibration quality analyzer; uses external precision non-inductive test loads and wide band current transformer. The Pulsed Model is compatible with all continuous output generators (same as standard model), plus generators with pulsed output waveforms.
-
product
Plug-in Test Systems
FAME is the innovative, modular plug-in test system for measuring and testing tasks in protection technology for medium-voltage and high-voltage switchgear. The plug-in test system combines complex switching operations for testing the function of current transformers and voltage transducers, as well as tripping and signal contacts.
-
product
Variable Frequency Series Resonance Test Device
WABP
Wuhan Sangao Electrical Test Installations Limit Co.
The device mainly AC voltage withstand test design for 10kV, 35kV, 110kV, 220kV, substation and line of all electric main equipment.Reactor with multiple separate design, Not only can meet the requirements of equipment testing conditions high voltage, small current, and can meet the requirements of low voltage AC voltage withstand test, has a wider scope of application.The device is mainly composed of variable frequency control power supply, transformer, reactor, capacitor divider.
-
product
Relay Test Set
RNT-5A
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.
-
product
Transformer Turns Ratio Meter
TTRM 102
SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.
-
product
Transformer Ratio Meters
Handheld Turns Ratio & Winding Resistance Tester TWR-H
TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.
-
product
High Current Calibrator
MC151
MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.