- Pickering Interfaces Inc.
product
Serial AC Power Sequencer
90-200-001
Each power outlet can be programmed to switched on in sequence with a specific timing delay. The delay can be staggered to ensure that order dependent systems - like PXI - can be switched on and off in an orderly way with just one operation. A staggered start up also limits the inrush current associated with the powering up of equipment, including earth current inrush, placing less stress on cabling and leakage breakers. Power on or off instructions can be initiated from either the front panel switch or via the serial interface.
-
product
Fault Trapper
#TFT100
Stop guessing about circuit breaker tripping issues. See why, when and where a circuit breaker trips. For the first time, you can detect the type of fault, and locate the position of an electrical “event” that causes intermittent and persistent circuit breaker trips, and No Fault Found (NFF) conditions. The critical information needed to reduce […]
-
product
Circuit Break Timer Test Set
PME-700-TR
The PME 700 TR combines portability, ease of operation and remarkable accuracy for the task of evaluating the condition and performance of medium and high voltage three phase circuit breakers of any kind.
-
product
Contact Resistance Meter
CRM 200B+
CRM directly measures micro-ohm values at 200A DC under live EHV switchyard conditions quickly & accurately. It is specially designed to reliably measure micro-ohm contact resistances of Circuit Breakers, Isolators, Busbar joints, earth switch joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards up-to 765 kV. SCOPE’s ability to make electronics work in such environment enables CRM to measure mili-volts signal in the presence of kilo-volts noise.
-
product
Modbus Gateway With Ethernet for Woodward GCP-30 Genset Controls and LS 4 Controls
GCP-MG
GCP-MG is a next-generation Modbus/CAN gateway specifically designed to interface Woodward's GCP-30 series genset controls (GCP-31, GCP-32), and LS 4 circuit breaker controls with Modbus networks. The GCP-MG gateway has been developed in cooperation with Woodward to ensure the highest possible degree of interoperability with Woodward equipment.
-
product
Digital Earth Resistance Testers
ST-1520
Capable of measuring earth voltage.2mA measuring current permits the testing of earth resistance without tripping earth leakage current circuit breakers in the circuit.Auto power off function.The timer operates automatically for approximately three to five minutes when the "push button switch" and "timer on button" are pressed together.
-
product
Portable Circuit Breaker Tester
PI-1600
The PI-1600 Circuit Breaker Tester incorporates modular design and flexibility to provide unequaled capability in a portable package. The PI-1600 test set is two testers in one, incorporating the PI-800 and PI-AUX. The PI-800 section can be used alone, on 120 or 240 VAC supplies, generating continuous current of 400, 800, amps at 4.2 kVA, with peak output to over 10x. When configured for the PI-1600, the PI-AUX output unit is connected in series or parallel to the PI-800. The PI-AUX boosts total power to 9.8KVA, and allows testing of draw-out breakers and MCB’s to 1600 Amps. The units are housed in rugged interlocking suitcase-size enclosures. Each piece weighs no more than 125 pounds, allowing one-person hand truck mobility. Basic operation is very simple, and the proven MAC-21 control instrumentation provides optimal output control and measurement. The MAC-21 instrumentation is supplied in a separate rugged portable case, interlocks on top of the PI-800, and connects to a cable in the rear of the test set.
-
product
Volt Probe & Socket Testers
Non-Contact & Socket
Use Amprobe non-contact volt probes to safely check circuit breakers, wall sockets and fuses for voltage presence with portable, economical tools. For sockets, choose an Amprobe socket tester, which can confirm whether GFCI breakers are properly wired.
-
product
Primary Test Equipment
LET-400-RD
It allows to perform with sufficient power, all the primary current injections to test the proper function and wiring of all the elements that compose the protection and measuring section in a substation.The regulation system is based on a continuously variable autotransformer (Variac) that supplies to a power transformer that delivers the high current outputs and isolate the main supply from the load. A built-in ammeter and a timer gives the information about the current value and the operation time of the relay or breaker under test.
-
product
40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger
SD750100G
Zhejiang Sandi Electric Co., Ltd
40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%
-
product
Contacts Resistance Tester
JYK II
•Instrument IPC architecture for domestic production of all models of metal contacts SF6 switchgear, GIS combination of electrical, vacuum switch, oil switch and column switches, contacts and so on.•Sensor: Acceleration speed sensor, rotation speed sensor, linear stroke sensorinstallation is very easy and simple.•Trigger: The trigger, external trigger, the sensor is triggered. Sensor can trigger the circuit breaker manually switching characteristic test, such as a manual column pole division switch.
-
product
Environmental Chamber
REXMED REC-200
MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc
-
product
Tan Delta and Capacitance Tester
TDC3100L
Tan Delta and Capacitance Tester TDC3100L is fully automatic 12 kV insulation power factor/dissipation factor (tan∂) test set designed for evaluating the nature and quality of electrical insulation materials and high voltage systems such as transformers, bushings, circuit breakers, cables and windings of rotating machines etc..
-
product
External Load Module
ELM
Circuit breakers are often overlooked during maintenance of electrical systems in aircraft, or often only verified for open and closed states. To test the true functional purpose of a circuit breaker it requires the application of current in excess of the rated trip value and then measure the time for the breaker to actually trip. This is the only way to verify that a circuit breaker will react as designed if an electrical failure occurs.
-
product
C/I Tracers
Circuit Seeker Kit
*Advanced patented non-directional sensing technology*Superior sensitivity and functionality providing for accurate tracing & locating*Ergonomic receiver with information-rich full-color graphical LCD*Graphics and audible signal provide quick and easy way to understand tracing feedback*Traces concealed wiring, locates junction boxes, and finds breakers for live or open circuits
-
product
Circuit Breaker Analyzers & Timers
CAT Handheld Series
When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.
-
product
Primary Injection Test Equipment
High current injection units for primary testing of over current relays and circuit breakers.
-
product
Circuit Breaker Test Systems
Crest has over a decade of experience of designing and manufacturing test systems for testing all the different kinds of switchgear and controlgear.
-
product
Dynamic Contact Resistance Meter
Dynamic contact resistance measurements are necessary to understand the condition of the arcing contacts of the circuit breaker. Static contact resistance measurements do not give us information related to erosion of arcing contact, misalignments of the contact, and damages to the driving mechanism.
-
product
Power Distributor
AV-P3040
"AV-P3040" can supply 40A (20A x 2). The power supply can be wired directly from the distribution board and equipped with two 20A breakers.
-
product
Safe Isolation & Lockout Tagout
Our range of Safe Isolation Kits and and our NEW lockout devices for isolating circuit breakers, RCD's and MCCB's, enable you to work safely on installations, following the safe isolation procedure, without the risk of electric shock. All our devices and equipment are easy to use and all equipment is supplied with Lockout Tags to identify the device is locked and who to contact in the event of an emergency.
-
product
Circuit Breaker Analysis System
Weshine Electric Manufacturing Co., Ltd
1. Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.
-
product
Transformer Rectifier Assemblies
Transformer rectifier assemblies are very useful in OEM applications when unregulated DC output is required. Input power can be single-phase or three phases. With single-phase input power, the output ripple is 50%. With three-phase input power, the output ripple is 5%. A 5% output ripple is a clear advantage. Hence, transformer rectifier assemblies with three-phase input power are more popular. Circuit breakers, fuses, voltmeters, and ammeters can be added per customer requirements. The assemblies can be an open frame or inside an indoor enclosure.
-
product
VARIABLE TRANSFORMER DC POWER
208163V
Motorized Variable Transformer Controlled Power Supply, P/N 208163VInput power: 208 VAC, 6 Amps, 3 PH, 60 HzOutput: 0 to 120 VDC, 16 Amps max.Ripple: 5%Manual control with variable transformerCircuit breaker / ON OFF on the 208 VAC, 3 PH input lineProtection fuse provided on the outputPOWER ON lightIndoor enclosure: 24H x 20W x 9DVoltmeter and ammeter are installed to monitor the output.All input/output connections are available inside the enclosureSystem includes main unit and remote assembly.
-
product
Automatic Relay Tester
The protective devices such as relays, overload coils, circuit breakers must be checked regularly to ensure that, they are always ready to operate correctly. If a fault occurs in the equipment, which they are protecting, routine relay testing will quickly detect the faulty, incorrectly adjusted protection circuits correctly. It is usually necessary to measure its operating time. The micro controller based time interval meter is used for this purpose in all AJIT brand relay testers.
-
product
Circuit Breaker Tester
LAN & Breaker
Find opens, shorts and mis-wired cable installations with quick go/no-go tests, using an Amprobe LAN tester. Identifying circuit breakers is efficient when you use an Amprobe breaker tracer.
-
product
Fuse Circuit Breaker and Fault Finder
Shanghai Beha Electronics Co., Ltd.
*is a Fuse and Fault Finder which comprises of two parts: The Receiver and the Transmitter.*Locating and tracing of cables*Finding Circuit Breaker/RCD
-
product
10 A portable digital micro-ohmmeter
MPK-253
The MPK-253 digital very low resistance ohmmeter is a portable, microprocessor-controlled instrument used to accurately measure resistances of switches and circuit breaker contacts, transformer and motor windings, wire and cable samples, joints in busbars, etc., using test currents from 1mA up to 10 A.
-
product
Dynamic Micro Ohm Meter
PRIME 600
It is the only micro ohm meter in the market that integrates both the contact resistance and the dynamic resistance measurement (DRM) for cost-efficient condition evaluation of contacts in SF6 and vacuum type circuit breakers; PRIME is a high current micro-ohmmeter that provides true pure DC with smart control up to 600 A, a wide measurement range with high power, dual ground testing process, thermal printer, touch display, pre-defined test modes and automatic reporting.
-
product
Bay Control
Schweitzer Engineering Laboratories, Inc.
Integrated bay control systems combine complete bay control with high-speed breaker protection, allowing you to deploy a full substation protection, control, and monitoring solution that is flexible for your application.
-
product
EHV Circuit Breaker Analyzer
DigiTMR S2
The Vanguard DIGITMR S2 is an inexpensive, easy to use digital circuit breaker analyzer. The DIGITMR S2 can be operated stand-alone or can be computer-controlled. It can fully analyze a circuit-breaker’s performance by testing the contact time, stroke, velocity, over-travel, and contact wipe. Contact and motion analysis can be performed for all breaker contact operations (Open, Close, Open – Close, Close – Open, and Open – Close – Open). Timing results are recorded and displayed on the 240 x 128 pixels back-lit LCD screen and can also be printed on the built-in 4.5″ wide thermal printer.