Filter Results By:
Products
Applications
Manufacturers
Charge Plates
acts as a capacitor whose discharge is measured.
- Virginia Panel Corporation
-
product
Charge Plate Monitor
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
product
Periodic Verification System for Measuring Static Charges and Verifying Ionizer Performance
STME-PVS
Statclean Technology (S) Pte Ltd
This meter is designed to measure static charges and to verify ionizer performance. It consist of three components- an Electrostatic Fieldmeter, a Detachable Plate and a Charger.
-
product
Electrostatic Products
We offer electrostatic measurement instruments for electrostatic discharge (ESD) and high-performance applications. Select from our reliable electrostatic sensors and detectors, voltmeters, charge plate monitors, and surface resistance/resistivity meters.
-
product
Basic Field Kit
PFK-101
The PFK-101 includes the PFM-711B Electrostatic Field Meter, CPM-720B Charge Plate Monitor and PCS-730B ±1 kV Electrostatic Charger for measuring ionizer decay and balance.
-
product
Field Meter
EFM-022
• This electrostatic field meter EFM022 is a hand-held field meter for precise measurement of electrostatic charges.• With the CPS022 accessory, the electrostatic field meter can be used as a charge plate monitor.• Precise measurement of static charges with automatic distance conversion (choice of 5 pre-set distances)• Operates on battery that can be supplemented with an AC net adaptor• With optional CPS022, can be used as a charge plate monitor for audit purposes and checking of ionization appliances
-
product
Electrostatic Field Meter - Hand Held Field Meter for Locating and Measuring Electrostatic Field Density
PFM-711B
- Lightweight, portable, hand-held Field Meter- Measure in 1 volt/in increments 0 to ±1,999 Volts- Measure in 10 V/in increments 0 to ±20,000 VoltsAccuracy of <±5%- LED ranging lights help position the meter at the right distance- Zero button allows the display to be adjusted to zero (0)- Hold feature freezes the measurement on the display- Use with Prostat CPM-720B Charge Plate Monitor and PCS-730B Electrostatic Charger- Use with Prostat PGA-710B AutoAnalysis System or X-Y Plotter- Analyze Footwear/Flooring Combinations- Verify Ionizer Balance and Decay Time Performance- 2-year Limited Warranty (1 year on the sensor)
-
product
Periodic Verification System
Model 775 PVS
The Simco-Ion Periodic Verification System Model 775PVS is a hand-held alternative to a charged plate monitor. It consists of three components-a fieldmeter, a detachable plate, and a charger for measuring static charge and verifying ionizer performance. Used alone, the fieldmeter measures electrostatic fields on any surface.
-
product
Charge Plate Monitors
Our charge plate monitors the voltage of the battery and the voltage of the battery.
-
product
Electrostatic Discharge
Our electrostatic discharge (ESD) measurement and control solutions include charge plate monitors, sensors, resistivity meters, and voltmeters. Reliably monitor, measure, locate, and test for static electricity.
-
product
Collapsible 6 Inch Charge Plate Monitor Assembly
CPM-760A
- 6" x 6" (15 cm x 15 cm) conductive plate- Total system capacitance of 20 pF ± 2 pF- Meets the requirements of ANSI/ESD STM3.1 and ANSI/ESD SP3.3- Designed to perform audits on overhead ionizers and room ionization systems- Flexible to also evaluate and balance bench top ionizers- Completely collapsible for compact storage- Designed to be used with the PFM-711A and PFM-711B
-
product
Autoanalysis System Set
PGA-710B
The PGA-710B is a unique electrostatic data analysis device for use with Prostat's PFK-100B Field Meter and Charge Plate Monitor kit. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions.
-
product
Ionization Test Set
PFK-105
- Ionization Test Kit for Measuring Offset Voltage and Discharge Times- Includes a Field Meter, Charge Plate Monitor, ±1000 Volt Charger and Decay Timer- Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification- Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.- Measure Body Voltage Generation and Decay- Evaluate Ionizers and Packaging Materials- Includes a fixture to hold the PFM-711B, CPM-720B and PDT-740B as one- Molded Carrying Case with Foam Insert Included
-
product
3-Component Quartz Force Rings
260 Series
Three-component quartz force ring sensors are capable of simultaneously measuring dynamic force in three orthogonal directions (X, Y, and Z). They contain three sets of quartz plates that are stacked in a preloaded arrangement. Each set responds to the vector component of an applied force acting along its sensitive axis. 3-component ring force sensors must be statically preloaded for optimum performance. Preloading provides the sensing elements with the compressive loading required to allow the proper transmission of shear forces. Versions are available with ranges up to 10k lb (45k N) in the z-axis (perpendicular to the top surface), and up to 4000 lb (18k N) in the x-and y (shear) axes. Both ICP® and charge output styles are available.
-
product
Charge Plate Monitors
Our easy-to-use charge plate monitors allow you to accurately evaluate air ionization systems used to neutralize static charge accumulation. Benefit from our economical solutions and products that offer onboard data storage to automate ionization system testing.
-
product
Walking Test System Kit
PGA-710
The PGA-710 Walking Test System is a complete kit designed to perform the walking test per ANSI/ESD STM97.2 and IEC 61340-4-5. The system consist of several devices designed for portability and to perform several different tests which includes measuring the voltage on a person in combination with floor materials and footwear.The kit includes the PGA-710B Data Logger, the PFM-711B Field Meter, CPM-720B Charge Plate Monitor, the PCS-730B Electrostatic Charger, Hand Held Electrode and the Prostat Autoanalysis Software version 2.0.
-
product
In-Line Charge Amplifiers
The in-line charge amplifier is used to excite structures or machinery with a definable impulse force. Resonances are identified by impulse, an important measurement parameter for the study of dynamic behavior. The 4705A1 is a fast turn on time, 50 mV/pc, in line charge amplifier with BNC jack connectors on each side.
-
product
Charge Logger Sensor
NUL-246
This sensor measures electrostatic charges. It can be seen as a highly sensitive electroscope indicating whether a charge is positive or negative. Other uses are: to explore the nature of static charge, to measure both charge and voltage, to measure charge by induction, quantify the charge on a capacitor or discover the charge distribution on a conducting sphere.
-
product
DC-DC Charge Pumps
Charge pumps – inductorless boost converters – from ams operate at up to 90% efficiency.
-
product
Accelerometer (Charge Output Type)
NP-2000 Series
This sensor converts mechanical vibrations into electric signals in proportion of vibration acceleration.You can choose the one that is ideal for your purpose,conditions,applications etc. from wide variety of selection.Charge amplifier is necessary because it is a charge output type,however, compared to pre-amplifier built-in type, it can be used at higher temperature in general.
-
product
Charge Sensitive Preamplifier-Discriminator
A101
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
product
Charge Amplifier
This compact Charge Amplifier has 3 signal routes.When it is used as the Charge Amplifier for the vibration analysis systemWave Stocker, all setups are possibleby the upgraded software.
-
product
DIFFRACTIVE DIFFUSION PLATES
LSD
Optcom Diffusion Plates Not Only Diffuse Light But Also are Available in Each Diffusion Level, Which Makes Them Ideal for Adjusting Light Quantity When Measuring Light Source Optical Characteristics. Ideal for light intensity adjustment. 5 types available depending on the degree of diffusion.
-
product
Charged Plate Monitors
Model 156A
The Trek Model 156A Charged-Plate Monitor System is designed to provide quantitative measurements of the effectiveness of air ionization systems, as to audit ionizer performance. The Model 156A employs a revolutionary charged-plate monitor design that utilizes an ultrahigh-impedance, high-voltage follower to monitor the ion collecting plate voltage.
-
product
Charge Controller
The intelligence of an AC charging station or an AC charging infrastructure is largely determined by the charge controller used. A smart charge controller has the primary task of controlling and monitoring the charging process of an electrical vehicle.The features that characterise a smart charge controller include communication with a backend system and the associated authorisation of users, as well as the efficient distribution of load currents by means of dynamic load management to prevent an overload of the existing AC system.
-
product
Thermal Image Plates
No longer are the firebricks and smoldering paper "tools of the trade" for researchers working with CO2 lasers. Now it''s possible to see IR laser beams in real time and with high resolution using a Thermal Image Plate from Macken Instruments. The characteristics of this instrument enable it to solve a wide range of problems. For example:
-
product
Plate Material Evaluating Cell
This quite handy cell is developed in order to evaluate plate material such as metal, semi-conducting plate, etc. In evaluation, a sample plate is sandwiched between cell blocks.
-
product
Parallel Plate Dielectric Test Cell
LT-4203A
The LT-4203A Parallel Plate Dielectric Test Cell is designed for measuring the AC loss characteristics and permittivity of solid laminates and panels per ASTM Standard D150‑98, and implements the guarded electrode (three terminal) measurement preferred as the referee method.
-
product
Charged Plate Monitor
Model 280A
Simco-Ion’s Model 280A incorporates enhanced circuitry that enables it to more accurately measure the performance of high frequency AC ionizers, as well as pulsed DC ionizers and steady-state DC ionizers. The Model 280A can be used as a portable CPM and is capable for of up to 6 hours of operation on the internal battery before recharge.
-
product
Charge Amplifier
ZET 440
Charge amplifier ZET 440 for piezoelectric detectors is intended for:*amplification and conversion of output signals of primary piezoelectric transducers with charge output;*amplification and conversion of output signals of primary transducers with the IEPE type in-built electronics to voltage;*gain ratios: 1, 10, 100;*LPF: 0.1, 1, 10 Hz
-
product
Slim & High-Performance Charge Amplifier
6001-A, 6002-A
Measuring a wide variety of vibration: automotive, rail transportation equipment vibration, motor/pump vibration, vibration response during vibration test. Also available for a vibration test device for calibration of equipment.