Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe High Density Precision Resistor Module
42-297A-121
The 40-297A-121 (PXI) and the 42-297A-121 (PXIe) are 4-channel programmable resistors with a range of 1.5 Ω to 925 Ω. They are part of the 40/42-297A series of high density precision resistor modules and provide a simple solution for applications requiring accurate simulation of resistive sensors.
-
product
DC Power Supply
◎PW-4063R
*Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-4063R as high as 0.01v and 0.001A.*Provide 4Pcs 10turns micro adjust VR for Voltage and Current adjustment. Easy to operate.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.
-
product
AC Resonant Test System
Yangzhou Power Electric Co., Ltd
Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
product
Pointer Insulation Resistance Tester
HT2533 / 772
Wuhan Huatian Electric Power Automation Co., Ltd.
Suitable for measuring insulation resistance of large capacity transformer, transformer, generator, high voltage motor and lightning arrester.
-
product
Load Cell Power Supply
MODEL PSMR
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
product
Tan Delta and Capacitance Tester
TDC3100L
Tan Delta and Capacitance Tester TDC3100L is fully automatic 12 kV insulation power factor/dissipation factor (tan∂) test set designed for evaluating the nature and quality of electrical insulation materials and high voltage systems such as transformers, bushings, circuit breakers, cables and windings of rotating machines etc..
-
product
1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester
TH2521
Shenzhen Chuangxin Instruments Co., Ltd.
TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.
-
product
Highly Inductive Resistance Meter
MR 8050
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
product
High Voltage AC/DC Testing Kits (Hipot Kits)
HV Testing Kits are used for testing of Motors, Generators, Switchgears, Cables, Transformers and other electrical equipment. These are used for testing & commissioning of HV electrical equipment. High Voltage AC Testing Kits are available in ratings from 25KV to 300KV AC in various mA and KVA Ratings.
-
product
AC DC Withstand Voltage & Insulation Tester (HI-POT)
SS71XX series
High voltage withstand and insulation tester (HI-POT tester) is used for testing insulation grade and withstanding voltage capability of electrical equipment, transformers, motor, relays, cables, electronic components, electronic applications, inductors, ignition coils, insulation wires, insulation tapes, valve coils, reactors, contactors, etc.
-
product
Potential Transformer Test Set
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.
-
product
Fully Automatic Transformer Winding Resistance Tester
Measure DC resistance of transformers windings etc. Introduction: The NMC ''TDR'' is a high precision, new generation, light weight large output current and micro-processor controlled tester. This replaces old DC wheat stone bridge and double arm bridge for measurement of DC resistance. ''TDR'' adopts new advanced test current power supply technology, four terminal measurement, digital display of resistance value and test current. ''TDR'' is powered by 220V AC mains single phase supply. The measurements are accurate as the test current is highly stable. High automation is achieved with automatic discharge warning.Principle: The constant current generated is fed to the resistance under test through the current terminals and the voltage drop across the resistance under test is measured and displayed in ohms. A true four terminal measurement is used to eliminate the need for lead resistance compensation.
-
product
MIL-STD-1553 PC/104+ Interface Module
PC104p-1553
Avionics Interface Technologies
Dual redundant, single or dual stream configurations - Transformer & Direct Bus Coupling - Concurrent Bus Controller, 31 Remote Terminals, & Bus Monitor operation - Full error injection and detection - Multi-level trigger for capture and filtering - IRIG-B time code encoder/decoder - Four high voltage (up to 30V) programmable DIO lines - Four trigger LVTTL Trigger I/O lines (2 input / 2 output) - ANSI Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, & VxWorks (others on request) - Conformal coating available - Designed for extended temperature operations - PC/104+ specification v2.2 compliant
-
product
Cylinder Type Transformer Systems
YDTW\YDTCW Series
Shanghai Jiuzhi Electric Co., Ltd.
Conventional AC test transformers are especially designed for testing objects of medium capacitance. These systems are particularly suited for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (inductive voltage transformers).The possibility of stacking several of these transformer modules allows reaching very high voltage levels by keeping reasonable floor space.
-
product
Variable Frequency Series Resonance Test Device
WABP
Wuhan Sangao Electrical Test Installations Limit Co.
The device mainly AC voltage withstand test design for 10kV, 35kV, 110kV, 220kV, substation and line of all electric main equipment.Reactor with multiple separate design, Not only can meet the requirements of equipment testing conditions high voltage, small current, and can meet the requirements of low voltage AC voltage withstand test, has a wider scope of application.The device is mainly composed of variable frequency control power supply, transformer, reactor, capacitor divider.
-
product
AC Current Transformers
CR Magnetics supplies an extensive line of toroidal current transformers for any need. Our offerings include measuring from 10,000 amps to a few milliamps. This includes ANSI, Commercial, Ground Fault, High Frequency, Wound Primary, DC Immune and Nano Alloy current transformers. Various outputs include 5 amp secondary, high turns ratio voltage outputs for both wire leads and pcb configurations. Our products are UL Recognized for both US and Canada.
-
product
MIL-STD-1553 Test & Simulation Interface for PCI
PCI-C1553
Avionics Interface Technologies
Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Real-Time recording and physical bus replay - PCI & PCIx Compatible, 3.3V and 5V OperationApplication interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software
-
product
DC High-Voltage Test Device
PGK 80
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PGK 80. The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions.* Continuous adjustable output voltage* The voltage measurement is done directly at the high voltage output* Timer of 1-30 min* Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal
-
product
800 Kv High Voltage Testing Transformer
GTU-800KVA/800KV
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
product
HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY
xPS Series
High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)
-
product
Test Set With Control Unit
Supreme Instrument Laboratories
Single Phase A.C. High Voltage Test set (BDV Flash Test) suitable for operation on 230 Volts, A.C. 50 Hz., designed for carrying out dielectric test on transformers, electrical switchgears, and installations. It operates on single phase A.C. and provides an output voltage zero to maximum rated voltage.
-
product
Extra-Ground Current Impuision Equipment
JYQ
Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.
-
product
Precision Multirange Current Transformer
P-2000
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
product
Burn Down Transformer
ATG 6000
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
product
Auxiliary Potential Transformers
Osborne Auxiliary Potential Transformers (Aux PT’s) are used in utility and commercial industrial power systems. Osborne works with our clients to identify the safety advantages of using auxiliary potential transformers (Aux PT’s) to establish protection schemes for high voltage equipment. Aux PT’s step the voltage down to safer levels, normally below 600 V AC.
-
product
Digital Insulation Testers
The Motwane Manufacturing Company
Motwane is India’s first company to design and develop an intelligent digital insulation tester that conducts insulation resistance tests on high voltage electrical equipment. Products like transformers, generators, motor cables, bushings, LAs, and switchgear, are prone to gradual degradation over time due to the adverse effects of temperature, humidity, and dust. The gathered test data allows clients to verify the current quality of insulation, and take appropriate action.
-
product
Surge Voltage and Surge Current Testing Systems
HIGHVOLT Prüftechnik Dresden GmbH
Pulse Voltage Test Systems are used for surge testing on transformers, cables, gas insulated switchgear (GIS), arresters, and other high voltage equipment.
-
product
1200kVA High Voltage Testing Transformer
GTU-1200KVA/600KV
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
product
Automation
The Transformers and measurement capacitors used in high voltage and Partial Discharge test equipment are typically reliable over several decades of continious use. The control technology is however typically obsolete after only 10-15years. MPS offers automated , state-of-the-art High Voltage Testing Equipment with the following features.
-
product
High Voltage Power Supplies
The mains voltage (230V / 3 x 400V) is transformed, rectified and filtered by the HN series. The direct current output voltage is tuned by a variable transformer or regulated by a thyristor controller. With the HS and HV series the rectified mains voltage is supplied to a frequency converter, which produces a mid-frequency square wave voltage. This transformed, rectified and filtered alternating current produces the desired voltage as output, which is regulated by means of frequency variation or pulse width modulation. The equipment in the HV series supply, in addition to the high voltage output, up to 3 auxiliary outputs which can be used to supply e.g. heating, grid voltage or surge voltage.
-
product
High Voltage Transformer
RR manufactures HIGH VOLTAGE TRANSFORMERS for various Industrial Applications.