Filter Results By:
Products
Applications
Manufacturers
-
product
Charge Sensitive Preamplifier-Discriminator
A101
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
product
Digital Multi Channel Analyzer
DT5770
The DT5770 is a compact portable 16k Digital MCA for Gamma Spectroscopy, integrating analog front-end with programmable gain and possible AC coupling. It is ideally suited for high energy resolution semiconductor detectors, like HPGe and Silicon, connected to a Charge Sensitive Preamplifier (CSP). The unit can also properly operate directly connected to a PMT with inorganic scintillators (e.g. Nal or Csl scintillators), provided exponential pulse shape and decay time above 200 ns.
-
product
Pre-Amplifiers
MPR, MDA series
MPR, MDR series provides low noise, high gain and wideband to improve dynamic range for emission testing. We also offer customized model for variable requirments.. Example 30M-1000MHz with band-pass filter Amprifier unit for connecting antenna directly
-
product
Transformer Preamplifier
SR554
Stanford Research Systems, Inc.
The SR554 is a low-noise, transformer-coupled preamplifier optimized for source impedances between 0.05 Ω and 1 kΩ. With an input noise of only 0.1 nV/√Hz, the SR554 can be used in a wide range of low-noise applications.
-
product
Preamplifiers
LNA Series
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
product
Charge Amplifier
ZET 440
Charge amplifier ZET 440 for piezoelectric detectors is intended for:*amplification and conversion of output signals of primary piezoelectric transducers with charge output;*amplification and conversion of output signals of primary transducers with the IEPE type in-built electronics to voltage;*gain ratios: 1, 10, 100;*LPF: 0.1, 1, 10 Hz
-
product
Charge Amplifier
CH-1200A
CH-1200A is a high-performance charge amplifier to convert charge signal to voltage signal. Built-in integration function allows optimization of the signal which is input to the vibration data analyzer connected.Changing into a multi-channel amplifier is easy by connecting multiple units.
-
product
Mm-Wave High Sensitive Power Meters
The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.
-
product
Thermal Sensitive Parameter Selector
UI9600
Parameter measured under normal temperature:1) β (0-99)2) Switching time T (0.01μs-99.9μs), including Tr, Ts, Tf3) VCES (0-2V), VBE (0-2V)4) Leakage current ICEO (0.01μA-99.9mA)5) Withstand voltage BVCEO (50V-650V)• Parameter measured under high temperature: VBE, β, ICEO
-
product
BJT Voltage Preamplifier
SIM911
Stanford Research Systems, Inc.
The SIM910 and SIM911 are low-noise, programmable preamplifiers which are ideal for a wide range of small signal applications. The primary differences between the two models are their input impedance and input noise.
-
product
Charge Amplifiers & Signal Conditioning
The use of charge amplifiers alongside piezoelectric charge output sensors is still widespread in many industries. This is due to the rugged and high temperature capabilities of the sensors. There are many challenges in using these sensors and it needs a good understanding of the technology to get a quality, noise free signal for accurate data.
-
product
Microphone Preamplifier
426A30
1/2-inch preamplifier with 7-pin LEMO connector (for externally polarized microphones)
-
product
Low Noise Preamplifier
The UPL-3001 preamplifier is a high performance solution for the low-noise amplification of ultrasonic signals. Designed for signals ranging from 0.5 to 300 MHz, the small and lightweight, rugged unit is perfect for remote applications. This is ideal for P&C, TT, AUT or TOFD inspection.
-
product
Charge Pumps
Renesas offers monolithic CMOS voltage conversion ICs that perform supply voltage conversions from positive to negative for an input range of 1.5V to 12V, resulting in complementary output voltages of -1.5V to -12V.
-
product
Lock-In Voltage Preamplifier
SR552
Stanford Research Systems, Inc.
The SR552 Voltage Preamplifier is designed to work with SRS lock-in amplifiers, providing gain where it is needed most?right at the experiment. The preamplifier minimizes noise and pickup in the connecting lines and can reduce measurement time in noise-limited experiments.
-
product
Universal Preamplifier 14
UP14
For Two Dimensional Magnetic Recording (TDMR) and Heat-assisted Magnetic Recording (HAMR) Headamplifiers. Universal Preamplifier 14 (UP14) is designed for TDMR and HAMR Head Amplifiers. With new Guzik RWA4000 TDMR, UP14 allows to process signals from three Read Channels. It also supports two high speed data channels for Write data and Laser data. UP14 has two channels for dynamic TFC control and allows to program TFC power per sector and close loop TFC power control in each channel. UP14 can generate two programmable modulation signals for write data and laser data with bandwidth up to 20 MHz. UP14 consist of two boards. The first UP14 RW Board processes high-frequency signals: read-back signals, write data and laser data. The second UP14 Control Board provides power, control and low-frequency signal generation: TFC, write data modulation and laser modulation.
-
product
Battery Charge and Discharge Tester
HTCFDK / 791
Wuhan Huatian Electric Power Automation Co., Ltd.
The voltage monitoring information of single battery is simple, safe and accurate with wireless relay access.
-
product
Microphone Preamplifier
426B03
Performance: Nominal Microphone Diameter:1/4"Frequency Response: (0.1 dB) (re 1 kHz)5 to 126000 Hz5 to 126000 Hz Frequency Response
-
product
Preamplifier
The UBBV series are external, extremely low-noise broadband preamplifiers that can be mounted to any SPECTRAN spectrum analyzer. They are ideally suited for spectrum analyzers and oscilloscopes as well as antennas of all manufacturers and are supplied with extensive accessories.
-
product
Time Sensitive Test Tools
We have developed a series of custom testing tools as part of our dedication to performing the most comprehensive testing in the industry. These tools allow for testing at lower layers than most commercially available tools and are available for use in your own testing labs. In addition, we have an extensive amount of T&M partner test tools which members of our testing services also have access to.
-
product
Preamplifiers
Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.
-
product
Time Sensitive Networks
Time Sensitive Network (TSN) standards enable deterministic real-time communication over Ethernet, allowing solutions to be built to provide extremely precise, predictable timing and control across the network. By adding features to Ethernet such as time synchronization, ingress policing, seamless redundancy, frame preemption, scheduled traffic, and stream reservation, TSN ensures data is not delayed by the network.
-
product
Highly Sensitive, Lightweight Backpack Radiation Detector (BRD)
identiFINDER® R700
The identiFINDER R700 Backpack Radiation Detector (BRD) offers new spectroscopic broad-search capabilities. Once dismounted, the identiFINDER R700 provides the capabilities required to successfully perform wide-area searches quickly and efficiently while offering exceptional sensitivity, communication, and trusted spectroscopic algorithms in a lightweight, ergonomic form-factor.
-
product
Battery Charge and Discharge Tester
HTCFD / 790
Wuhan Huatian Electric Power Automation Co., Ltd.
The voltage monitoring information of single battery is simple, safe and accurate with wireless relay access.
-
product
Endevco Cryogenic Charge Output Accelerometers
PCB's acquisition of Endevco's full line of testing sensors means all Endevco sensors are now backed by PCB's Total Customer Satisfaction (TCS) guarantee. Endevco® cryogenic piezoelectric accelerometers are built specifically for measuring vibration under cryogenic conditions down to -452° F (-269° C). Signal outputs of these units are very stable even at extremely low temperatures. Their rugged internal construction is designed to withstand multiple cycles of thermal shock with steep temperature gradient. The accelerometers are self-generating devices that require no external power source for operation and contain no electronics. This allows them to operate below the -320° F (-196° C) limit of ICP accelerometers, down to -452° F (-269° C).
-
product
Charge System Safety
Renesas' charging system safety circuits are optimized to provide a redundant safety protection to an Li-ion battery charging system by monitoring input voltage, battery voltage and charge current.
-
product
DC to 350 MHz Preamplifier
SR240A
Stanford Research Systems, Inc.
The model SR240A 350 MHz Preamplifier is a 4-channel, DC-coupled instrument with a gain of 5 per channel. The amplifiers can be used independently or cascaded to provide gains of 5, 25, 125 or 625.
-
product
Microphone preamplifier
PRE-01
The microphone preamplifier PRE-01 has been designed to match Audiomatica’s microphones MIC-01, MIC-02 andMIC-03. It is particularly useful when the microphone has to be operated far from the analyzer or when weighted measurements are needed. PRE-01 powers the microphone connected to its input with an 8.2V phantom supplyand adds a selectable weighting filter (A or B or C); also available there is a 20 dB gain stage
-
product
Lock-In Voltage Preamplifier
SR550
Stanford Research Systems, Inc.
The SR550 Voltage Preamplifier is designed to work with any SRS lock-in amplifier. Preamplifiers provide gain close to the experimental detector, before the signal-to-noise ratio is permanently degraded by cable capacitance and pickup
-
product
Microphone Preamplifier
HT426E01
Nominal Microphone Diameter1/2Frequency Response Electrical Noise(at 22 C) (Flat 20 Hz to 20 kHz)Distortion (3 V rms input at 1 kHz)<-70 dB<-70 dB[1] EnvironmentalTemperature Range (Operating)-40 to +248 FExcitation Voltage 20 to 32 Constant Current Excitation 2 to 10 mA