Filter Results By:
Products
Applications
Manufacturers
Ion
charged particle.
-
product
Ion Chromatography
Metrohm IC Driver 2.1 for Empower®
Software drivers for integrating Metrohm IC instruments in "Empower® 3" made by Waters. One license per computer authorizes the operation of IC systems under "Empower® 3".
-
product
PXIe-4154, 2-Channel, 8 V, 3 A PXI Programmable Power Supply
781155-01
2-Channel, 8 V, ±3 A PXI Programmable Power Supply—The PXIe‑4154 is a specialized programmable power supply for battery simulation. It is designed to simulate a lithium‑ion battery cell’s transient speed, output resistance, and 2‑quadrant operation (source/sink). Critical to many RF and wireless applications, the simulator’s fast transient response time allows it to rapidly respond to changes in load current with minimal voltage dip, which makes the PXIe‑4154 ideal for powering devices under test (DUTs) such as RF power amplifiers, cellular handsets, and a variety of other mobile devices. To model the behavior of a battery more accurately, you can use the onboard programmable output resistance to simulate a battery’s internal resistance. For quiescent and standby current measurements, the PXIe‑4154 features integrated current measurement.
-
product
Analytical Services
Surface Analysis; X-Ray Photoelectron Spectroscopy (XPS, ESCA), Auger Electron Spectroscopy (AES), Time-of-Flight Secondary Ion Mass Spectrometry (Static) (TOF-SIMS), Dynamic Secondary Ion Mass Spectrometry (D-SIMS). Microscopy & Diffraction; Organic Material Analysis; Bulk Chemistry.
-
product
Ion Chromatography
Hyphenated Techniques
Extend the scope of ion chromatography by interfacing your Metrohm IC with various sampling system and detection techniques
-
product
Ion Chromatography
Eco IC
Discover Eco IC, an ion chromatography system that focuses on the essentials while not compromising on quality, robustness, and reliability. Eco IC has been developed to enable more users to benefit from this technique. Whether you need to perform routine water analysis or you’re looking for an instrument for higher education, Eco IC comes with all the components you need. In addition, you can also save time and reduce work by getting an automated system.
-
product
Water-soluble Ion Analyzer
WAGA-100
Sample gas passes through denuder, and soluble gas will be analyzed by ion chromatograph first; the aerosol will then be inflated and given into ion chromatography to analyze soluble aerosol.
-
product
Air Ion Counter
The Air Ion Counter is a handheld meter designed to measure ion density-- the number of ions per cubic centimeter (ions/cc) in air. It measures this number separately for positive and negative ions (+ and - ions are usually present simultaneously). This instrument is a true ion density meter, based on a Gerdien Tube (Gerdien Condenser) design, and it contains a fan which pulls air through the meter at a calibrated rate. The standard model measures up to 2 million ions/cc (for comparison, outdoor air typically has 100 to 1000 ions/cc, both + and -). The 2 million range is sufficient for almost all situations except for measuring very close to electric ionizers or strong radioactive sources.
-
product
Failure Analysis
A partial list of our state of the art test equipment, applicable to these testing disciplines, will include the following: Two Scanning Electron Microscopes with EDS (SEM/EDS) Three Differential Scanning Calorimeters (DSC) Three Thermogravimetric Analyzers (TGA) Three Thermo Mechanical Analyzers (TMA) One Dynamic Mechanical Analyzer (DMA) Two Real-Time Fluoroscopic X-ray Systems, including a Microfocus System One Fourier Transform Infrared Microscope (FTIR) (capable of identifying a single particle of an unknown material) Two Ion Chromatographs (IC) (capable of identifying ionic impurities in ppm)
-
product
Charge Plate Monitor
The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.
-
product
Multi-Protocol Wireless Application Networking System with Open, Integrated, Secure & Scalable System for Data Aggregation & Viewing
Ion
Jacobs’ vendor agnostic architecture was designed and implemented with the goal of an open Industrial Internet of Things (IoT) solution. ion© adapts and applies technology that enables our customers to gain efficiencies and savings, through connecting our client’s sites then collecting and displaying data in a unified interface. This provides custom insights to our clients, empowering them to ensure safety and respond quickly. The Jacobs ion© solution has been operationally deployed for over a decade and enables innovative approaches for data accuracy, data timeliness, and safety — greatly improving information flow and productivity.
-
product
Vacuum Quality Monitor Systems
The 835 VQM is a mass spectrometer that operates from UHV to 10-5 Torr and accurately measures the gases in the vacuum chamber. The 835 VQM Differential Pump System delivers the advantages of the 835 VQM at higher pressures. The VQM system consists of an autoresonant ion trap mass spectrometer gauge, a VQM Controller and VQM Viewer software that that converts raw data into actionable information. The system is ratiometric, meaning that it determines the ratio of each gas to other gases in a vacuum chamber. It is usually coupled with a total pressure gauge to provide partial pressures of each gas as indication of the quality of the vacuum in the chamber.
-
product
Pressure Measurement
When operating below the Pirani gauge range (10-3 mbar), an ion gauge can be used to measure pressure. There are a range of gauge heads and filament materials to cover specific pressure ranges and vacuum requirements in this region. The VACGEN ion gauge heads operate using the same principle but vary in design and construction to most accurately monitor pressures within specific ranges.
-
product
Redox (ORP) Sensors
ORP sensors measure the oxidation-reduction potential—the tendency to gain or lose electrons when a solution comes in contact with a chemical substance. ORP measurements are used to ensure that a solution has been completely reduced or oxidized. ORP sensors are often used in tandem with pH sensors, which measure the hydrogen ion activity in a solution.
-
product
Multi-probe for Ammonium and/or Nitrate
S470
S470 is a complete family of Ion selective electrodes (ISE) probes suitable for monitoring the performance of the ammonium ion (as NH4+ or NH4–N) and nitrate ion (as NO3– or NO3–N) in a liquid matrix.
-
product
Sodium Ion Concentration Pocket Water Meter
LAQUAtwin Na-11
The only pocket meter that directly measures sodium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B). Unique sensor allows measurement of viscous liquids, solids, and even powder samples. No need for a beaker to calibrate your meter or measure a sample. Just place few drops of the standard or sample onto the flat sensor. This procedure saves you time and prevents wasting your precious sample.
-
product
Sodium Ion Concentration Pocket Water Meter
LAQUAtwin Salt-22
The only pocket meter that directly measures sodium ion concentration in 0.3ml sample (or 0.05ml sample with sampling sheet B) and converts it into salinity or NaCl salt concentration. No need for a beaker to calibrate the meter or measure a sample. Just place few drops of the standard or sample onto the sensor. This procedure saves you time and prevents wasting your precious sample.
-
product
Liquid Chromatograph Mass Spectrometer
LCMS-8040
The LCMS-8040 was designed to provide significantly higher sensitivity while maintaining the high speed offered by the LCMS-8030. Ultrafast MRM transition speeds, up to 555 MRMs per second (dwell times of 1 msec and pause times of 1 msec) are achieved. In addition, the LCMS-8040 features the polarity switching at 15 msec and high speed scanning rate of 15,000 u/sec. By incorporating newly improved ion optics UF-Lens™ and UFsweeper™ II collision cell technology, the LCMS-8040 provides higher multiple reaction monitoring (MRM) sensitivity. This higher sensitivity expands the potential range of LC/MS/MS applications.
-
product
GC Time-of-Flight Mass Spectrometer
PEGASUS® BT
Today's laboratories are being asked to do more everyday—more samples run, more data acquired, more chemical information processed, and more results achieved—all in less time, for less money. With LECO’s Pegasus BT users will get all of the data they need from a single sample run, without the need for additional laboratory support. Unique and powerful software and hardware features simplify quantitation while also identifying more components with increased sensitivity. A StayClean™ ion source virtually eliminates the need for source cleaning, while a convenient benchtop package saves valuable space in the laboratory. The Pegasus BT will give users more uptime, improved chemical data, and an increase in overall productivity and efficiency.
-
product
Potentiostat Galvanostat
EnergyLab XM
EnergyLab XM is an application specific XM instrument designed for research of batteries, fuel cells, and supercapacitors. EnergyLab XM’s extreme sensitivity is used for advanced testing of lithium ion batteries and alkaline batteries. This includes research in half-cell configurations and next generation low impedance cells in the sub 100 μΩ range as well as popular battery types such as 2032 coin cell testing and 18650 cell testing.
-
product
Single Cell Battery Chargers
Renesas offers single-cell battery chargers that extend the life of lithium ion (Li-ion), lithium polymer (Li-polymer), and lithium iron phosphate (LiFePO4) batteries.
-
product
Chloride Ion Test Kit for Surfaces
134S
Elcometer 134S test method: a latex sleeve is filled with a Chlor*Rid extract solution and stuck to the test surface where the solution is worked against the surface to extract the salts. The titration tube is inserted and the results can be recorded.
-
product
DC-DC Power Supplies
Advanced Conversion Technology, Inc
Units are available for use in extreme temperatures and other harsh conditions. We also offer products that meet specific military standards including MIL-STD-704A requirements for handling high voltage spikes and MIL-STD-1275 specifications for low input voltage transients. DC-DC power supplies can be VME rack mounted, bench mounted or installed in a ruggedized frame. High and low voltage units are available, as are hermetically sealed ion pumps and shipboard power supplies.
-
product
Oxygen Purity Monitor
CI1300
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
CI1300 Oxygen Purity Monitor is designed for monitoring oxygen purity in the room air. It uses advanced ion current sensor as its measure unit, is an intelligent monitor based on the core micro-processor. Can precisely monitoring the oxygen purity in 0-40% N2 & O2 gas mixtures. - See more at: http://en.ci-ele.com/79b7fcd3-aee7-30a4-9cf8-76748ef33dcc/37450a04-f65c-a3b7-4e5b-7053fb48529d.shtml#sthash.UZqzsqpD.dpuf
-
product
Battery Cell Formation System
17000 series
Chroma 17000 series is specifically designed for the formation of Lithium Ion and Lithium Polymer secondary batteries. The 17000 series is a complete turn-key system, including carrier trays, robust battery probe contacts, high quality charge/discharge modules and intuitive software all under computer control. Patented Battery Voltage Tracking (BVT) DC-DC conversion power modules minimize power consumption in battery charging, and Energy Recycle Modules (ERM) recycle the discharged energy directly back to the DC power system for increased power efficiency. These power saving designs provide a planet friendly solution along with cost savings by reducing energy consumption. The intuitive software provides a flexible selection in the charge/ discharge channel, current rating, and modules under test. These features allow the Series 17000 to be used for final cell development, pilot line production, high volume production and ongoing reliability monitoring/quality control.
-
product
Ion Beam Sources
Veeco offers the most comprehensive array of ion beam sources for a broad range of applications, including the industry's only Linear gridded sources.
-
product
Application Specific LC Systems
Nexera Organic Acid Analysis System
The Nexera Organic Acid Analysis System has been well-received in the fields of food and environment as a highly selective high-sensitivity system. It uses separation by ion exclusion chromatography and Shimadzu’s unique detection technique (pH-buffered electric conductivity detection). Recently, this system is being utilized by even more users in a wide variety of fields, and its usage in the fields of pharmaceuticals and life science is increasing.
-
product
Battery Cell Simulation / Emulation
BMS
Efficiency, reliability and safety of modern lithium ion batteries for electric vehicle drives strongly depend on the battery management system (BMS) as their electronic control unit.
-
product
Calibration
ION Science recommends that your instruments are recalibrated on an annual basis to ensure they continue to provide you with accurate, reliable results and that they maintain their extended warranty. Choose the right calibration solution from our range below.
-
product
Software
Production Triangular Voltage Sweep (TVS) Option
Materials Development Corporation
In traditional TVS measurements, the operator must select the end points of the mobile ion peak todetermine the area to analyze. Though the selection of these points is a simple matter for the operator, the required input precludes using this technique in asemi-autonomous production environment. The goal of TVS Production testing is the rapid determination of mobile charge concentration with little or no operator input. The test methodology must be compatible with production environments where accuracy, easeof use, and minimum operator involvement are of paramount concern. Also, the possibility of automated wafer handling must be considered.
-
product
Secondary Ion Mass Spectrometry (SIMS Analysis)
Rocky Mountain Laboratories, Inc.
Secondary ion mass spectroscopy is operated either in the dynamic mode (DSIMS) or the static mode (SSIMS). DSIMS is useful for profiling impurity and trace elements through films and interfaces. SSIMS is useful for characterizing polymeric materials and only measures the outermost molecular layer of a specimen.