Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI/PXIe LVDT/RVDT/Resolver Simulator Module, 4-Banks
43-670-001-AABBCC
The 41/43-670-001 is ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire VDT or resolver, or dual 4-wire utilizing a shared excitation signal.
-
product
Current Transformers
Excellent measurement technology requires high-quality current transformers. The product portfolio comprises a wide range of current transformers for load currents (operating currents) and residual currents (RCM). Different designs cover a variety of installation situations and metrological requirements, and enable retrofitting. AC/DC sensitive measuring current transformers use a special measurement method to detect both AC and DC currents of different frequencies.
-
product
Combined Transformer
Combined Transformer is a great solution for projects with dimension restrictions. Because we focus on quality and reliability of our products our combined transformers also require minimum maintenance once installed.
-
product
Automatic Transformer Tester
CVCT-S20
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.
-
product
Standard Current Transformer
HL / 640
Wuhan Huatian Electric Power Automation Co., Ltd.
It is used as the calibration standard of current transformer in the error test of transformer.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
DC Power Supply
◎PW-4063R
*Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-4063R as high as 0.01v and 0.001A.*Provide 4Pcs 10turns micro adjust VR for Voltage and Current adjustment. Easy to operate.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.
-
product
50Hz-100kHz LCR Meter
Chroma 11022/11025
Chroma Systems Solutions, Inc.
The Chroma 11022 and 11025 LCR Meters are passive component testers that can give you the most cost effective alternative equivalent to the high priced meters. They are designed for the demanding applications in production test, incoming inspection, component design and evaluation. Programmable test signal level settings are from10mV to 1V in a step of 10mV, and the VM/IM signal level monitor functions allow you to evaluate your devices at the level you specify. Ten test frequencies of 50Hz, 60Hz, 100Hz, 120Hz, 1kHz, 10kHz, 20kHz, 40kHz, 50kHz, and 100kHz, can be used to evaluate passive components and transformers/ LF coils.
-
product
Winding Resistance Meter
TRM 25
SCOPE introduces 25 A state of the art precision winding resistance meter, specially designed for field testing as well as factory testing of large transformers up to 500 MVA. Winding resistance value of transformer and rotating machine are directly displayed on 5.7” TFT display. TRM 25 is designed to work in live EHV switchyard conditions, ensuring operator’s safety and repeatability of results. Maintenance time saving is ensured by one time connection to transformer with simultaneous resistance measurement of three / six windings, measurement of resistances of all taps with automated tap change and demagnetization facility. The meter is protected against the back-EMF offered by large inductive windings.
-
product
CT & PT Test Kit
PCT200i
PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
-
product
Distribution Transformer Tester
NDB-DOC™
The NDB-DOC™ is a test instrument designed for distribution networks transformers from 10kVA to 2500kVA. It can determine the presence of short circuits or an open circuit in the distribution transformer primary winding & also short circuits on the secondary winding. The NDB-DOC™ is designed to be operated from an arial device or from the ground at the end of a hot stick without disconnecting the transformer’s secondary windings.
-
product
AC Resonant Test System
Yangzhou Power Electric Co., Ltd
Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
product
Surge Arrester Testing
SCAR 10
This MOV- Metal Oxide Varistor test system is the perfect device to perform analysis and diagnostics on metal oxide arrestors. It is supplied with a special current clip-on transformer designed for the measurement of current leakage.
-
product
SF6 Filled High Precision Standard Capacitors
YL Series
Shanghai Jiuzhi Electric Co., Ltd.
The SF6 insulated standard capacitor is used as Capacitance standard in measuring bridge Circuits to measure the dielectric dissipation Factor tanδ of all types including cables, capacitors, bushings, instrument transformers and power transformers. Further-more, It can be used as high-voltage capacitor for voltage divider circuits of high-voltage transformer test.
-
product
Relay Tester
LET-4000-R
Regulation and Measurement Module performs the regulation of the DC current and is made with a variable auto transformer (Variac) regulating a three phase DC current, with a power of 8KVA and a three phase transformer of 8KVA with 2V nominal power in the secondary windings. A built-in ammeter and a timer give the information of the current injected and the operation time of the relay under test.
-
product
Pointer Insulation Resistance Tester
HT2533 / 772
Wuhan Huatian Electric Power Automation Co., Ltd.
Suitable for measuring insulation resistance of large capacity transformer, transformer, generator, high voltage motor and lightning arrester.
-
product
PD Monitoring systems
TECHIMP PD Hub™
Techimp’s Partial Discharge (PD) Monitoring systems usually consists of a Central Unit and distributed Data Acquisition Units – the PD Hub™ - able to acquire and process the PD signals locally detected through PD sensors installed on each of main electrical assets (generator, transformer, HV cables and GIS).
-
product
SMART MEGOHMMETER
MD-5060x
The Megabras MD-5060x is a smart, microprocessor-controlled, 5 kV insulation tester. Besides the conventional measurement of insulation resistances up to 5 TΩ, its advanced features allow to automatically measure both the Polarization Index and Dielectric Absorption Index, thus significantly simplifying testing of transformers.
-
product
Three Phase Power Analyzer
Model PA-600
Power Analyzer Model PA-600 is having advanced measurement capability which gives accurate measurement also at low power factor such as 0.1PF with 0.1% basic accuracy. 16 bit microcontroller and 24bit Analog to digital converter performs accurate measurement & calculation of Voltage, current, power, power factor, crest factor, form factor and frequency with any load and signals of frequencies from 30 Hz to 800 Hz. PA600 is most applicable for no load and full load testing of distribution and power transformer. You can read true RMS value, peak value, mean value and average value of any parameter simultaneously in LCD display.
-
product
Power Transformer Monitoring
Optimize the efficiency of your transformers by relying on our flagship DGA monitoring system with long-term stability, no maintenance needs, no false alarms and a revolutionary method for detecting ambient air ingress.
-
product
Split type AC Current Transformer
CTF-200T
MULTI MEASURING INSTRUMENTS Co., Ltd.
*1A output for metering application.*Wire stopper is equipped for the slipping protection.*The special connector is not necessary as the output terminals are provided.*Open circuit protection and nonflammable plastic material.
-
product
Resistance Measuring Device According to DIN EN 61557-4 (VDE 0413-4)
PeakTech Prüf- und Messtechnik GmbH
An extremely robust milliohm measuring device in a splash-proof hard case for professional field service use, e.g. for resistance measurement on motor coils, generators and transformers or for continuity testing on ring bus systems in industrial plants.
-
product
Power Quality Analyzers
APQM-702/APQM-703
*It can be powered from the L phase.*It is intended for use in virtually all types of networks from 64 V to 760 V directly, with special consideration for measurements on low-voltage poles, due to its ease of connection.*It has an independent power supply and is therefore particularly suitable for measurements outside of voltage transformers. It can also be adapted for measurements on DC voltage systems.*Real-time remote configuration and data transfer (GPRS) using a built-in GSM modem
-
product
Transformer Resistance Testing
Weshine Electric Manufacturing Co., Ltd
Transformer insulation resistance deterioration is one of the most common causes of transformer failure: a failing transformer is a costly replacement in an electrical system with the potential for a long downtime. If you fail to maintain your transformer with regular insulation resistance testing (as can be carried out by the WESHINE Transformer Ohmmeter (VS-3110 series) of transformer test equipment) then it’s likely to fail before reaching its maximum operating life.
-
product
Uniload Voltage Transformer Test Set
2J6
The Type 2J6 Knopp Uniload Voltage Transformer Test Set consists of three major parts: When the Knopp Precision Transformer in the 2J6 set is compensated for, and used with, a secondary burden of 15 volt-amperes, for example, the ratio of this precision transformer is well within 0.02% and the phase angle is well within 2 minutes. The transformer, in common with other Knopp Precision Multirange Transformers, is wound so that it has practically the same ratio and phase angle accuracy on all ranges.
-
product
Test Switches
Series FT
An industry standard for CT & VT isolationfor instrument transformer and connected device testing.Up to 10 poles; Numerous configurations availableTypically mounted on switchgear and relay panels10 pole test plug available; UL and cUL recognized.
-
product
Power Transformer Automatic Test Device
XD71
Hangzhou Xihu Electronic Institute
The device is used for power transformer power outage routine test items to do automated testing.Which is characterized by dielectric loss, insulation resistance, DC resistance, tap-changer switching characteristics, short circuit impedance and variable ratio of six test items are concentrated in an instrument,so that the instrument function, test power and test lead height fusion.Field test, just start wiring once, at the end of unplugging wiring once,the middle process by the test personnel in the computer terminal to send command control,the test system automatically completes all or part of the above test items.
-
product
Load Cell Power Supply
MODEL PSMR
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
product
AC Test Transformer Products
Shanghai Guantu Technology Co., Ltd.
Manufacturing scope:Output voltage: 0~200kVOutput capacity: 0~20kVATechnical features of AC test transformer:Light weight; adopting oil-filled and air-filled structures reduces weight by 20% year-on-yearStatic noise; uniform electric field design and special fastening structure, no discharge and no mechanical noise at rated outputHorizontal iron core structure reduces the center of gravity of the equipment to a low pointMulti-flange combination with high structural strengthKey parts are cushioned with advanced elastic materialThe control box has complete protection functions and strong overload capacity
-
product
HDBaseT Transformers
Pulse HDBaseT transformers are designed to provide common mode noise reduction for improved EMI performance and support power over HDBaseT (PoH) applications of up to 100W. The HDBaseT technology enables 5Play feature set, which includes ultra high definition 4K video, audio, 100BASE-TX Ethernet, various control signals, and up to 100W of power, on a single 100m/328ft CAT5e/6 cable.
-
product
Regenerative AC Emulator, 600 VAC, 63 A, 45 KVA, 3‑Phase
SL1202A
The SL1200A series was designed to handle all your 3-phase AC test needs up to 1200 VAC, from 30 kVA to 630 kVA without the need for a transformer. Two voltage ranges are available: 600 VAC and 1200 VAC. The 600 VAC models are ideal for low voltage inverter test as well as EV and EVSE charging test applications. The 1200 VAC models allow for (HVRT) testing at the IEC LV-AC limit without the need for a large, complex test setup.