Filter Results By:
Products
Applications
Manufacturers
- TEAM SOLUTIONS, INC.
product
DC-to-250MHz 1:100 Oscilloscope Probe Kit (HP-9258)
PRB-HP-9258
The Oscilloscope Probe 1:100 - HP-9258 is a low-input capacitance high voltage 1:100 oscilloscope probe with a bandwidth of 250 MHz designed and calibrated for use on scopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with oscilloscopes having an input capacitance of 10 - 35 pF.
-
product
Magnetometer
MFM-1
For the measurement of magnetic equilibria such as the earth's magnetic field and for the determination of anomalies and biologically active location factors. The external measuring probe is connected to the measuring device by a probe cable, as a result of which an exact probe guidance is possible in places which are difficult to access. The disturbance source can be localized by the directional characteristic of the measuring probe.
-
product
Polarity Tester
PT-1
International Electro-Magnetics, Inc.
The PT-1 provides a simple and easy way to determine the relative polarity of coil windings. It allows for an in-process test that takes a minimum of time to perform. By placing a coil on the platform and making connection to the start and end of a winding, a test signal is induced in the winding. The induced signal is low level and completely safe for the operator. By comparing the test signal phase of the coil under the test output, the relative polarity is indicated by the Red/Green LED. The tester operates by inducing a signal voltage in the coil under test by means of a magnetic flux field. The field is generated by a coil located in the probe base. The coil configuration is designed to provide optimum field distribution. We have also applied this basic circuit to a 5-channel scanning unit.
-
product
Near Field Probes 30 MHz up to 3 GHz
RF6 set
The RF6 near field probe set consists of 2 passive magnetic field probes and 2 passive E field probes for measurements in the development phase of the E-field and magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF6 set allow a step by step localization of interference sources of the RF magnetic field and RF-E-field on an assembly. From a larger distance the electromagnetic interference is detected by RF-R 50-1 for the magnetic field and by RF-E 02 for the E-field. The RF-B 3-2 and RF-E 10 probes with their higher resolution can more presicely detect the interference sources of the magnetic field and the E-field. Field orientation and field distribution on an electronic assembly can be detected by special guidiance of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
product
Single Sheet Tester
Model SST500X500
Gopal Make single sheet tester SST is developed as per IEC 60404-3. It can be attached as probe to Ep400 Main unit and user can test specific total loss, specific apparent power, and r.m.s value of magnetic field strength as well as B/h curve in the software.
-
product
HandyScope HS6-DIFF With EMI & SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMEG-W5
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEG EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
product
Gaussmeter
DX-105
DX-105 Gaussmeter is a desktop gaussmeter. Which is based on the latest progress of the Hall Effect magnetic field measuring instrument.Adapt the high stability constant current source circuit technology to design and manufacture. Test probe adapts imported GaAs linear Hall-chip, the difference between any two probes is small, which can be replaced directly when it is damaged. DX-105 Gaussmeter is an ideal DC magnetic field test instrument.
-
product
Near Field Probes
MFA Family
The micro probes allow detailed measurements of high-frequency magnetic fields in the layout, at the smallest SMD components(0603-0201) and at IC pins of printed circuit boards.
-
product
Three-axis Hall Magnetometer
THM1176
The THM1176 family combines the performance of a professional Hall instrument with the usability of a consumer USB device. Its range goes from the µT to 14 T, DC to 1 kHz, with ±1% accuracy. It simultaneously measures all three axes of the magnetic field, so you get a true field strength reading no matter how you hold the probe. The entire instrument has been reduced to a cable with a few fat spots, which can plug directly into your PC or into a battery-powered handheld computer. The result is the most compact, lightweight, low-power, go-anywhere and measure-anything magnetometer in the world. Teslameter Gaussmeter 3-axis
-
product
Probes, Magnetic Field
EM-6880 | 9 KHz – 520 KHz
The EM-6880, EM-6881 and EM-6882 Magnetic Field Probes operate in conjunction with any 50 ohm input impedance receivers.
-
product
Microrad RF Fieldmeter
Users can measure from static/almost static magnetic fields up to 6GHz utilising only two probes while remaining compliant with Directive 2013/35/EU. This solution is the NHT-3D meter plus 33P and 01E probes
-
product
Zero Field Cavity
Zero field cavities generate a zero magnetic field in an air gap. They are mainly used to calibrate hall probes for their zero scale value of output for the magnetic field strength H or the magnetic flux density B they measure. For example Gaussmeters can be calibrated by using Zero Field Cavity.
-
product
Near Field Probes 30 MHz - 6 GHz
XF Family
The XF family consists of 4 passive magnetic field probes and 3 passive E field probes designed for measuring magnetic and E-fields in ranges from 30 MHz to 6 GHz during the development phase. Due to their integrated impendance matching the probes are less sensitive in the lower frequency range than the RF type probes.
-
product
Magnetic Flaw Detector
CDX-Ⅲ
magnetic particle flaw detector is the self-designed magnetic participle flaw detector of MITECH CO.,LTD. With small size, light weight, easy operation, multifunction in one unit. The detector can equip A, D, E O four types of probes to realize the functions of magnetic clamp detection, electromagnetic yoke detection, cross magnetic yoke detection, ring detection. It is the necessary detector to do quality control, safety check, life evaluation in the fields of petrol, chemicals, metallurgy, shipbuilding, aviation, railway etc
-
product
Coating Thickness Gauge
CM8855
It meets the standards of both ISO2178 and ISO 2361 as well as DIN, ASTMand BS. It can be used both in the laboratory and in harsh field conditions. The F probes measure the thickness of non-magnetic materials (e.g. paint,plastic, porcelain enamel, copper, zinc, aluminum , chrome etc.) on magneticmaterials (e.g. iron, nickel etc.) . often used to measure the thickness ofgalvanizing layer, lacquer layer,porcelain enamel layer, phosphidelayer, copper tile, aluminum tile, some alloy tile, paper etc. The N probes measure the thickness of non - magnetic coatings on non-magnetic metals .It is used on anodizing, varnish, paint, enamel,plastic coatings, powder, etc. appliedto aluminum, brass, non-magnetic stainless steel, etc. Automatic substrate recognition. Manual or automatic shut down. Two measurement mode: Single and Continuous Wide measuring range and high resolution. Metric/Imperial conversion. Digital backlit display gives exact reading with no guessing or errors. Can communicate with PC computer for statistics and printing by the optional cable. Can store 99 groups of measurements. Statistics is available.2.SPECIFICATIONSDisplay: 4 digits LCD, backlitRange: 0~1250 μm/0~50mil (other ranges can be specified )Min.radius workpiece: F: Convex 1.5mm/Concave 25mmN: Convex 3mm/ Concave 50mmMin. measuring area: 6mmMin.Sample thickness : 0.3mmResolution: 0.1 μm (0~99.9μm);1 μm (over 100μm)Accuracy: ±1~3%n or 2.5 μm or 0.1mil(Whichever is the greater)Bttery Indicator: Low batter indicator.PC interface: with RS-232C interfacePower supply: 2x1.5 AAA(UM-4) batteryOperating condition: Temp. 0~50℃ .Humidity <95% .Size: 126x65x35 mm; 5.0x2.6x1.6 inchWeight: about 81g(not including batteries)Standard accessories:Carrying case ...................1 pc.Operation manual ............ 1 pc.F probe in built .................1 pc.NF probe in built...............1 pc.Calibration foils ..............1set.Substrate (Iron) ................1 pc.Substrate (Aluminium)......1 pc.Optional accessories: RS-232C cable & software:1.USB adaptor for RS-232C2.Bluetooth interface
-
product
Zero Gauss Chamber
ZGC
The model ZGC zero gauss chamber reduces the environmental magnetic field (Earth field) to near zero inside the chamber. Any gaussmeter probe which is less than 9.4 mm or 0.370" diameter can be placed inside. The meter is then "zeroed", which means that it will read zero whenever the probe is subsequently placed in zero field. By using a zero gauss chamber, any offset error is therefore eliminated. The model ZGC is unique in that it contains a degausser (demagnetizer). This is situated between the inner and outer mu-metal shields. When the degauss button is pressed, any accidental magnetization of the chamber, no matter how strong, is erased. Accidental magnetization is a major problem with most zero gauss chambers and it has limited their use. If a magnet comes too close, the chamber will become "permanently" magnetized and will have an internal field that is typically 0.2 to 0.5 gauss. The chamber must then be degaussed because the Earth field is also around 0.5 gauss, so a magnetized zero gauss chamber will not significantly reduce the field.
-
product
Magnetic Field Meter
MP - 2000
The new magnetic field meter MP - 2000 first used probes (tangential and Axialfeldsonden), in which an own microcontroller, the analog sensor signals are digitized and linearized directly in the probe. This new technique is extremely trouble-free and allows very precise measurements, especially at high magnetic field strengths, where Hall probes can not operate linearly.
-
product
Reference Magnets
Series MT
The reasonably priced WUNTRONIC standard reference magnets offer the possibility in a simple way of being able to calibrate or to check magnet measuring instruments like Gauss Meter/Tesla Meter with the respectively accompanying probes in a defined magnetic field.
-
product
Helmholtz Coil
In the measurement of magnetic fields by means of Hall probes or measuring coils it is necessary to calibrate the instruments in a known magnetic field. Our standard field coil according to Helmholtzenables to production of a magnetic field calculable with high accuracy from the dimensions and the amperage. In series arrangement with an accurate ammeter field strengths of up to 800A/cm are produced. The dield room accessible both in axial and radial direction. Helmholtz coils with fluxmeters are also useful in testing of magnets. Helmholtz coils give repeatable results as against the search coils due to which the magnets can be compared with more accuracy for their total flux and in turn their quality. Field Generating and Field Detecting Helmholtz coils are designed as per user specifications.
-
product
HandyScope HS6-DIFF With EMI, SureConnect & SafeGround: 1 GS/s, 250MHz BW, 4 Channel (256MS/ch), USB Differential Digital Storage Oscilloscope, Spectrum Analyzer, Voltmeter, Transient Recorder
HS6-DIFF-1000XMEGS-W
The powerful capabilities of the WiFiScope HS6-DIFF-1000XMEGS EMI analyzer give the user the possibility to quickly perform a good EMI compliance test. With this cost effective test, time and money are saved by avoiding extra visits to expensive EMC testing facilities. The supplied EMI probe set TP-EMI-HS6 contains three magnetic field (H field) probes and one electric field (E field) probe. The tripod ensures that the probes can be positioned properly at the object under test.
-
product
Scanning Probe Microscopy
SPECS Surface Nano Analysis GmbH
As Scanning Probe Microscopy (SPM) is a key tool for nanotechnology, SPECS offers dedicated solutions for highly demanding requirements.In UHV, strong emphasis lies on spectroscopic methods such as scanning tunneling spectroscopy and inelastic tunneling spectroscopy as well as single atom and molecule manipulation. With the invention of a Joule-Thomson cryostat by Prof. Wulf Wulfhekel, SPECS now offers the JT-STM , operating sample and sensors in thermal equilibrium below 1K with optional high magnetic field.
-
product
Near Field Probes 30 MHz up to 6 GHz
XF1 set
The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
product
Tesla Meters & Adapters
Projekt Elektronik Mess- und Regelungstechnik GmbH
Magnetic field measuring devices, also known as magnetometers or gaussmeters, which we market under the product name Teslameter, together with one of our probes, form the individual solution for a measurement task. The basic principle at Projekt Elektronik is the modular structure, which allows the combination of different probes with a magnetic field measuring device. This means that our components can be flexibly adapted to the respective requirements. A great advantage for the everyday practice of our customers.
-
product
Vector Magnetometer
FVM400
Macintyre Electronic Design Associa
The FVM400 uses fluxgate technology to measure the three vector components of the magnetic field. The fluxgate sensors are packaged in a 1" square by 4" long probe that is connected to the handheld electronics unit by a modular telephone cord. The sensor can be located up to 100 feet from the electronics unit.
-
product
EMC Near Field Probes
TBPS01
The TBPS01 EMC near field probes H20, H10, H5 and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation.
-
product
Magnetic Field Measurement Systems
The magnetic field probe performs non-contact current measurements and can be used for real traces. The probe of higher resolution enables pinpoint measurements.
-
product
TEM Cells
Transverse Electro Magnetic (TEM) cell or Crawford cell (named after its inventor) is used to generate accurate electromagnetic waves over a wide frequency range: DC (0 Hz) to GHz., EM waves generated in the cell propagate in transverse mode and have the same characteristics as a plane wave. It can be used to calibrate E-field broadband probes for testing radiated E-field immunity as well as for measuring radiated emission from a product with a spectrum analyzer/EMI receiver.TEM cell generates a consistent electromagnetic field for testing small RF devices such as wireless pagers, receivers, portable phones, etc.
-
product
Cryogenic Probe Station
CPX-VF
The Lake Shore CPX-VF probe station enhances the standard probe station capabilities with the addition of a ±2.5 T vertical field superconducting magnet. It can do all the standard C-V, I-V, microwave, and electro-optical probing of the CPX, plus out-of-plane vertical field superconducting magnetic measurements. Researchers can use it to perform Hall effect measurements and test magneto-transport parameters. The CPX-VF is one of Lake Shore’s premium probe stations for combining microwave measurements with magnetic field.
-
product
Gaussmeter
460
The Model 460 is a 3-channel, high-resolution gaussmeter, for use with single or multi-axis probes. It is capable of measuring magnetic fields from 0.001 Gauss to 300kGauss, with a DC accuracy +/- 0.10%. This unit is designed for demanding applications, such as material analysis and field mapping, where low-noise, high-resolution magnetic measurements are necessary. Measurements of AC and DC magnetic fields are shown in Gauss or Tesla on the two-line vacuum fluorescent display. The Model 460 features RS232C and IEEE-488 ports, allowing the instrument to be controlled via a remote computer or automation equipment. The Model 460 can be used with a 3-axis probe or with three separate single-axis probes, effectively providing three Model 450 gaussmeters in one instrument. Probes are sold separately, and are available in a wide range of constructions.
-
product
Electromagnetic Radiation Analyzer
SEM-600
Beijing KeHuan Century EMC Technology Co,.LTD
Broadband Electromagnetic Radiation Analyzer SEM-600 can accurately measure various complex electromagnetic environments. The probe covers all frequencies from low frequency to microwave radiation. It can measure electric field strength and magnetic field by equipping different types of probes. Intensity (magnetic induction) and power density, it is also equipped with ordinary probes and other weighted probes based on human safety standards.
-
product
Relay / Magnetic Field Testers
PeakTech Prüf- und Messtechnik GmbH
Ideally suited for checking magnetic fields and the correct function of coils, e.g. Relays and solenoid valves. The magnetic field detector works without contact, so that opening the housing is not necessary in most cases. When a magnetic field is detected, the probe tip lights up permanently blue, with clocked relays in the same cycle as they are controlled. The function of the magnetic field detector can be checked before each measurement with the enclosed test permanent magnet.