Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
LXI High Voltage Switching - 3-Bank, 1-Pole, 12:1 Multiplexer Plugin Module
65-231-905
The 65-231-905 plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
Xilinx Zynq ARM + FPGA SoM
TE0720
Sundance Multiprocessor Technology Ltd.
TE0720s are industrial-grade SoC modules integrating a Xilinx Zynq Z020 SoC, a gigabit Ethernet transceiver (physical layer), 8 Gbit (1 Gbyte) DDR3 SDRAM with 32-bit width, 32 Mbyte Flash memory for configuration and operation, and powerful switch-mode power supplies for all on-board voltages. A large number of configurable I/Os is provided via rugged high-speed stacking strips. All modules in 5 x 4 cm form factor are fully mechanically and largely electrically compatible among them. All this on a tiny footprint, smaller than a credit card, at the most competitive price. A free and open embedded development suite with reference designs is included.
-
product
DC - 400 MHz PC-Based Timer Interval Analyzer
GuideTech’s GT658PCI is an ultra-fast, high resolution, DC – 400 MHz Time Interval Analyzer (TIA), ideal for most PC-based lab bench (timing) test applications. What makes the GT 658 superior to traditional counters is analogous to the difference between volt meters & digital scopes. While both measure voltage, the scope provides much more information about the dynamics of the signal. This is because our patented TIA substantially increases measurement speed, and the measurements are displayed as afunction of time. All of these features, along with the benefit of ‘continuous time correlation to a common reference between all measurement time stamps,’ enable our TIAs to make measurements that weren’t previously possible with traditional counters.
-
product
Automated Potentiometer Systems
Measurements International Ltd.
Intrinsically Accurate Self-Calibrating Ratio Divider, Best Accuracy < 0.05 ppm, Built-in 20-Channel Scanner, Arbitrary Voltages from 1 mV to 1200 V, Bipolar Voltage Measurements, Calibration of Fluke 5700A/5720A, Calibration of 3458A and 8508A, Calibration of Voltage Ratio Dividers (F752A, MI 1340A, G7520), Linearity Calibration of Digital Volt Meters (DVM), Traceability to 10 V Zener Reference.
-
product
Load Cell Power Supply
MODEL PSMR
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.
-
product
Electrical Tester
C.A 742
The C.A 742 Voltage Absence Tester is an essential tool for any electrician to check that no voltage is present before working on an electrical installation connected to the network. It complies with IEC 61243-3 Edition 3 and can be used to work on any indoor or outdoor 600 V CAT IV installation. To fulfil the requirements of the standards and legislation in certain countries, there are 2 references, with or without IP2X accessories.
-
product
NI-6581B, 100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO
783887-01
100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO—The NI-6581B is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO, creates a digital instrument for interfacing with 54 single-ended digital pins. A digital I/O adapter module for FlexRIO can be used to do real-time interfacing of standard protocols and implement customized protocols. The NI-6581B can operate sample digital waveforms at up to 100 MHz. It includes support for common transistor-to-transistor logic (TTL) voltage levels, or other voltage references can be sourced externally using a front panel connector.
-
product
Software
Junction Measurement and Analysis
Materials Development Corporation
A comprehensive set of analyses for junction diode or Schottky barriers begins with C-V data gathering that adjusts the voltage step to the slope of the C-V characteristics. This assures an optimum set of C-Vdata whether the voltage range is small or large. Doping profile and resistivity profile are both available at the touch of a key. Plots of 1/C2 - V or Log(C) - Log (V+ phi) show doping uniformity and doping slope factor. Exclusive recalculation options allow adjustment of stray capacitance and area to facilitate calibration using a standard reference wafer of known doping or resistivity.
-
product
DC Power Supplies
Is the unidirectional flow or movement of electric charge carriers (which are usually electrons). The intensity of the current can vary with time, but the general direction of movement stays the same at all times. As an adjective, the term DC is used in reference to voltage whose polarity never reverses.
-
product
300nA NanoPower Voltage References
ISL21080
The ISL21080 analog voltage references feature low supply voltage operation at ultra-low 310nA typ, 1.5µA max operating current. Additionally, the ISL21080 family features guaranteed initial accuracy as low as ±0.2% and 50ppm/°C temperature coefficient.
-
product
IP67 DC Blocking Splitter Combiner
PD5033
INSTOCK Wireless Components, Inc
PD5033 is an IP67 outdoor, weather resistant, DC blocking, three way, RF broadband, 50 ohm, power divider, power combiner furnished with N type coaxial connectors. The passive Wilkinson design passes RF and the 10 MHz reference signal through both ports while blocking DC current. This configuration is typically used in combining applications to prevent passing DC to the sum and adjacent ports. Max voltage rating at the DC blocked ports is 50 VDC. All wireless band applications in the frequency range from 698 to 2700 MHz are covered with best in class RF performance. The RoHS compliant PD5033 is a bidirectional device capable of 40 W max microwave input power levels in both power splitter and combiner apps. See 3 way power divider input rating tables for additional power handling info.
-
product
Phase ID Systems
LED Meter Probe allows the user to take Real time Phase Angle readings along with AC nominal voltage readings. A PD800W LED Meter Probe works in conjunction with the Receive Unit to verify phase identification along with the actual phase angle data. This is all done without any calculations or data transfer from the field to a base computer. The meter probe and reference probe or receive unit can operate at 100 feet of separation and up to 300 feet line of sight separation. In the event that this distance would need to be greater, the Receive Unit can be unplugged from the charging cable and taken into the field while operating on it's rechargeable batteries for up to 8 hours at a time.
-
product
Series Voltage References
Analog Devices offers a broad line of series voltage references with low dropout, low power, and excellent line regulation. These devices are voltage references that are functionally similar to a three-terminal regulator. Some series voltage references are designed to also operate in shunt mode by biasing the output pin and leaving the input pin open circuit. Series mode voltage references have the advantage that they draw only load and quiescent current from the input supply.
-
product
NI-6581, 100 MHz, 54 Single-Ended-Channel Digital I/O Adapter Module
780565-01
100 MHz, 54 Single-Ended-Channel Digital I/O Adapter Module for FlexRIO—The NI-6581 is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO, creates a digital instrument for interfacing with 54 single-ended digital pins. You can use the NI-6581 to do real-time interfacing of standard protocols and implement customized protocols. The NI-6581 can operate sample digital waveforms at up to 100 MHz. It includes support for common transistor-to-transistor logic (TTL) voltage levels, or other voltage references can be sourced externally using a front panel connector.
-
product
VME Analog Output Module
DP-VME-2115
DP-VME-2115 is an industrial standard 24 channel D/A (Digital to Analog) board. It incorporates most of the features which are demanded in industrial applications. Each Digital to Analog Converter (DAC) is provided with a separate reference voltage selection either from internally generated reference or from the external input. This external input reference signal is passed into the protection circuits before it is fed to any active components. The input protection circuit is designed for ± 25Vp-p input ranges. The DAC output may be unipolar or bipolar and the output is jumper selectable, which is routed to the VME P2 connector, with short circuit protection of upto 30mA.
-
product
Reference Meter
SB1300
Shenzhen Star Instrument Co., Ltd.
The SB1300 three-phase multi-function reference meter incorporates 32-bit floating point DSP, wide-range measuring and embedding industrial PC technologies. This model was the first approved by China National Institute of Metrology. Star Instrument has been granted the first manufacturing license for class 0.02 reference meters. Basic measuring range (phase voltage): 1V~480V, current measuring range: 1mA~120A; wide measuring range (phase voltage): 0.1V~1000V, current measuring range: 0.1mA~200A
-
product
HBM Verification Tester
HBM-VT
High Power Pulse Instruments GmbH
- HBM pulse generator verification tester according ANSI/ESDA/JEDEC JS-001 up to ±10kV- To be used in HBM test and qualification labs for regular pulse generator specification compliance test in order to fulfill lab audit and certification requirements- Fully automatic compliance test and verification of HBM pulse generators regarding ANSI/ESDA/JEDEC JS-001 normative standard at 3 different load conditions: Short Circuit, 500 Ω, and a reference diode at VBR=15 V reverse breakdown voltage, including DC test- Parameter evaluation and verification of the transient HBM current waveforms: Peak Current, Rise Time, Decay Time, Maximum Ringing Current- Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, 8010C, HBM-TS10-A hardware systems in combination with HBM-S1-B (6kV) pulse generators (upgrade on request)- Fully automatic test report generation (PDF)- Electrically floating (no fixed system ground): The HBM loads, current sensor output, USB control interface and the enclosure are electrically floating. There is no limiting system ground which may introduce common-mode interference induced HBM current measurement errors.- Isolated industrial full-speed USB control interface- Isolated power supply derived from USB port- Compact size 126mm x 82.5mm x 44.5mm
-
product
5VA Reference Supply, DC input
PS5410C-16
The PS5410C-16 is a 5VA AC Reference Power Supply, available with many transformer isolated output voltages at different frequencies. Input power is either 12 VDC or 15 VDC. The standard 15 pin "D" connector simplifies interconnection to other equipment.
-
product
2 Channels, 28-115 Vrms, 47 Hz-2.5 kHz (max. range) programmable
AC3
The module is used to provide an AC signal source when a secondary reference source other than the optional on-board reference module is required. The modules are programmable for full range voltage outputs from 2 to 115 VAC, and frequency from 47 Hz to 10 kHz.
-
product
AE Valve Leakage Detector
SVLD1
Through acquisition, processing, and calculation of acoustic emission signal of the valves, SVLD1 could generated root-mean-square voltage (RMS), average signal level (ASL) and power (P) parameters as which could judge the leakage. Meantime, you can pre-calibrate the leakage quantity for the specified valve, and calibration curve of parameters and leakage could be calculated by SVLD1, so as to give the valve leakage reference value during the test.
-
product
Universal PD & EMI analyzer
Spark P3
Doble Spark P3 is a universal partial discharge (PD) and electromagnetic interference (EMI) analyzer that uses a software defined radio signal detector to identify characteristics of insulation system deterioration that could lead to the failure of high voltage equipment. It detects signals from suitable sensors in a frequency range between 9 kHz to 2 GHz for PD and EMI, and DC to 500k Hz for acoustic and reference voltage measurements.
-
product
Digital Tank Test Kit
4109
The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `
-
product
Three-phase Fully Automatic Test System
TS41
Calmet Smart Calibration Devices
The Calmet TS41 test system consists of a three-phase reference meter of accuracy class 0.02% (or 0.04%) and an integrated three-phase current and voltage source up to 3x120A/600V. It makes possible automatic testing of electricity meters in meter test stations
-
product
3 Phase Reference Standard
ZERA® COM5003
The COM5003 Reference Standard is part of the ZERA/Powermetrix high precision measuring instrument series. With the highest accuracy of 0.005 % (50 ppm), the COM5003 presents its new innovative digital technology and extended features for measurement. As a primary standard, the COM5003 is designed for testing current and voltage meters as well as single- or three-phase power and energy meter testing systems. This precise technology is especially useful in metrological institutes, official utility lab applications, and other environments for energy suppliers or manufacturers of electric meters and designed for integration of existing systems. All operation, measurements and data visualizations can be viewed using by the COM5003’s simple user interface and 9“ touchscreen.
-
product
Single Phase Site Energy Meter Test Instrument Type KP-P1001-A
Bofa Instrument & Equipment Co., Ltd
Single phase site energy meter test instrument type KP-P1001-A (without voltage and current source) is an ideal instrument to test all kind single phase energy meters accuracy below 1.0, especially for meters on site. During tests, the tested meter must be on load condition (that means the tested meter must be working). The instrument tests the errors by comparing energy impulse from the tested meter with energy impulse from the reference meter inside the instrument.
-
product
Thermocouple Vacuum Gauge Tubes
DV-6 Series for Medium Vacuum
Teledyne Hastings, manufacturer of the original DV-4, DV-5, and DV-6 thermocouple vacuum gauge tubes, produces vacuum measurement equipment with exceptional stability, accuracy, and reliability under the most demanding conditions.The Teledyne Hastings’ DV-6 series thermocouple vacuum gauge tube acts as a localized sensor which is then paired with a selection of meters or controllers to provide reliable, cost-effective measurements in diverse applications. The robust sensor gauge tube is easily installed into vacuum systems and when properly excited, generates a thermoelectric voltage to provide a vacuum pressure measurement based on gas density. The DV-6 thermocouple vacuum gauge tube fully compensates for temperature and rate of temperature change.Thermocouple gauge tubes are calibrated on vacuum systems that contain N2 or Air, but can be used with other gases. Additionally, thermocouple gauges and their controllers can be recalibrated when a replacement thermocouple gauge tube is installed, following instructions in the manual. However, our DB-20 reference tube is available to confirm meter/controller performance. A complete line of installation accessories are also available to simplify the integration of our thermocouple gauge tubes into a variety of vacuum systems. Our goal is to provide “one less thing to worry about”, when performance matters! With a wide range of meter, fitting, relay and output options, the DV-6 series provides a reliable pressure measurement in numerous industries and applications.
-
product
Reference Oscillators
DDC Connectivity Power Controls
DDC's quadrature power oscillators supply two outputs that are 90° out of phase, to provide both the reference and quadrature signals, simultaneously. This, combined with their small size and scalable output voltage and frequency capabilities, make them an excellent choice for use in Inductosyn applications.
-
product
Phase Detectors
Macom Technology Solutions Holdings Inc.
MACOM's MSPD Series Integrates an SRD reference frequency multiplier, coupling capacitors and a Schottky diode microwave sampler / phase detector in a 0.075” by 0.100” hybrid. They are used to phase lock microwave oscillators up to 22 GHz to a much lower reference frequency by deriving a locking voltage from the sampled RF and the multiplied reference.
-
product
Three Phase Site Energy Meter Test Instrument Type KP-P3001-A
Bofa Instrument & Equipment Co., Ltd
Three-phase site energy meter test instrument type KP-P3001-A (without voltage and current source) is an ideal instrument to test all kind three-phase energy meters accuracy below 0.2, especially for meters on site. When we want test a meter errors, the tested meter must be on load condition (or we can say the tested meter must be working). The instrument can test the errors, by comparing energy impulse from the tested meter with energy impulse from the reference meter which inside the instrument. The equipment is box structure and weight is very light, easy to carry, it is very convenience to test the installed meters on site.
-
product
SENSORBOX MODULE
MDGDSSBM
*Turn your MDMAX, MDMAX2A or MDMAX3 into a unique sensor simulator to substitute known good waveforms for intermittent components that cannot be verified*Sensor simulation tests include: DC voltage, fixed frequency, pre-defined waveform and hand-drawn waveform*Contains a library of standard reference waveforms that can be modified by the stroke of a finger
-
product
20 Channel Multiplexer (2/4-wire) Module for DAQ970A and DAQ973A
DAQM901A
20 Channel Multiplexer (2/4-wire) Module. High voltage switching capability of up to 300 V and built-in thermocouple reference junction.