Filter Results By:
Products
Applications
Manufacturers
- Virginia Panel Corporation
product
Enclosure, 10 Module With 3 Cable Clamps
410112252
This aluminum enclosure is for ITA Part # 410 104 123 and allows your 10 Module Solution to be customized to your needs. The cable clamps are 1" ID. ITA strain relief plates are not needed.
-
product
Earth Ground Clamp
1630-2
The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes.
-
product
Earth Ground Tester
1625-2
The Fluke 1625-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1625-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes.
-
product
High Voltage Insulating Tester
Suitable for preventive maintenance of gapless arresters.By simply clamping around the ground wire of an arrestor with a clamp CT, it detects leak current and leak current resistance components.
-
product
Easy Pole Clamp-On Ground Resistance Tester w/ Super Slim Jaw
FT6380
The FT6380 measures grounding resistance simply by clamping to multiple-grounded ground wires. No auxiliary grounding rod is needed, and there is no need to disconnect the ground wire from the grounding rod. The compact, low-profile sensor can be used to clamp ground wires with ease, and also provide AC current measurement functionality and can measure currents ranging from leakage current on the order of several mA to load currents of up to 60 A.
-
product
Ground Grid Tester
GGT Series
The GGT500 ground grid integrity tester is designed for inspection of the substation ground grid. It can also be used as a portable micro-ohmmeter with Both Sides Grounded and Remote Control functionalities. It is intended to inspection the conditions of a grounding system beneath substations, testing of medium- and high-voltage circuit breakers, disconnecting switches, high-current bus bar joints, cable splices, and different high-current links.In the United States when inspecting the quality of the grounding systems beneath a substation, the proper procedure is to inject 300 A DC during a time period of 60 s. This is what the GGT500 will do, and in that time period, the current path and voltage drop are checked. Also acting as a micro-ohmmeter, the GGT500 can test low resistance values by producing high test currents of up to 500 A.The instrument is placed in an unbreakable, plastic case with IP67 protective rating (with closed lid). Although very portable and lightweight, micro-ohmmeters have very high output power capabilities. High output voltage enables a wider measurement range at higher test currents, as well as the use of thinner/longer test cables. GGT500 ground grid integrity tester generates a true DC ripple-free (less than 1 % ripple) current with automatically regulated test ramps. This significantly decreases magnetic transients and ensures great accuracy.When used for testing in Both Sides Grounded conditions, a special current clamp powered from the ground grid integrity tester is used for measuring a current through groundings. If even a higher safety level is required, the remote control feature enables the operator to perform measurements from a distant location, away from the instrument and test object.
-
product
Ground Resistance Clamp Meter
61-920
*Auto ranging*Auto power off*Hard case included*2-year warranty
-
product
Earth Ground Resistance Meter
1623-2
The Fluke 1623-2 earth ground tester measures earth ground loop resistances using only clamps, only stakes, or one clamp and stakes. With the stakeless test method, the Fluke 1623-2 is able to measure earth ground loop resistances for multi-grounded systems using only current clamps.
-
product
Digital Ior Leakage Current Clamp Tester
MCL-400IR+
MULTI MEASURING INSTRUMENTS Co., Ltd.
・About Ior Leakage CurrentRecently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).
-
product
Ground Resistance Tester
2521
Shenzhen Chuangxin Instruments Co., Ltd.
*High measuring accuracy, high speed, easy to use, especially suitable for using in laboratory and automatic testing line *Test current AC / 5 ~ 30 (a), resistance Ω (0 ~ 600 m), time (1 ~ 99 s) shows at the same time;*Test time can be arbitrary setted;*Test alarm value can be arbitrary set up *Pass/fail sound and light alarm;
-
product
Earth Ground Clamp Meter
T2000
T2000 is a professional clamps specially developed to evaluate resistance of earth rods with no need to disconnect any part of the system (STAKELESS METHOD)
-
product
PE/ Ground, Insulation Resistance Tester
Handheld
The safety testers of the Handheld class are used to measure PE/ Ground resistances, insulation resistances and to perform a simple functional test. The small and sturdy universal testers are intended for standard-compliant safety tests in workshops and production as well as for mobile operation during repair, installation, service and more.
-
product
Ground Earth Resistance Tester
2678X
Shenzhen Chuangxin Instruments Co., Ltd.
Ground Earth Resistance Tester verifies the integrity (continuity) of the protective bonding of the equipment (Class I equipment) designed to secure safety through the basic insulation and protective earthing. It is also called earth (ground) bonding test. If the continuity of the protective bonding is confirmed, we can conclude that the equipment has the requirements for preventing electric shock even if the insulation between the primary circuit and the accessible conductive section fails and a fault current flows through the distribution system.
-
product
Clamp Earth Resistance Testers
Is used for earth resistance test. This meter uses an EBTN screen with a dual display function (the resistance & current displayed). It also has functions such as a real-time clock, data storage, data review, alarm, and automatic shutdown.
-
product
Programmable Ground Resistance Tester
AllWin Instrument Science and Technology Co., Ltd.
Executive test in 40A/60A of UL60950-1Test resistance range 0~510m ohmOutput current range 5~40A
-
product
Ground Resistance
Provide accurate and reliable measurements of both ground resistance and soil resistivity for installation and troubleshooting.
-
product
Ground Bond Tester
HYAMP® Series
HYAMP III includes productivity-enhancing features and proven safety technology to reduce the compliance bottleneck on the production line. All models verify the integrity of your product's ground circuity with accurate 4-wire measurements and offset capability.
-
product
Current Clamps
Due to its variable measuring functions, the digital clamp meter can be operated universally. Useful details, such as the large display, manual or automatic ranging and measurement position lighting, makes operation particularly easy and reliable.
-
product
Current clamps
Precision ammeters determine the intensity of an electric circuit without interrupting the current flow.
-
product
Absorbing Clamps
The absorbing clamps also known as ferrite clamps are used for measuring disturbance power on power input lines as well as other auxiliary I/O lines.
-
product
Current Clamp
The program of current clamps offers a wide range of functions and opportunities. Nieaf-Smitt offers you 10 current clamps, each with its unique specifications. Whether you need a basic instrument or a more advanced model, the portfolio has the correct instrument available. Even a CAT IV model is now available in our range.
-
product
Clamp Meters
Basic functions:AC current: 40/400/1000ADC current: 40/400/1000AAC voltage: 4/40/400/750VDC voltage: 400mV/4/40/400/1000VResistor: 400/4/40/400K/4/40MTemperature: -20 to +750°CFrequency: 10/100/1000Hz/10/100kHz/10MHzDuty cycle: 0.1 to 99.9%Capacitance: 5nF/50nF/500nF/5μF/50μF/200μFSpecial functions:Auto rangingNCVDiodeContinuity buzzerLow battery displayData holdRelative data holdAuto/manual range shiftZeroAuto power-offOverload protectionSampling frequency: 3 times/sMaximum display: 3999Maximum open distance of clamp mouth: 55mmGeneral characteristics:Color: iron gray and orangeNet weight: approximately 274gLCD size: 46 x 32mmSize: 245 x 90 x 33mmPower: 1 x 9V and 6F22Packing content:CartonHandheld bagEnglish manualTesting leadBatteryTemperature probe
-
product
Ground Set Tester
Self-contained, portable convenienceThis tester provides an easy way for an electric utility to check the resistance in protective grounding sets used by line personnel.
-
product
Ground Fault Locator
K-800
Kongter Test & Measurement Co., Limited
Kongter’s K-800 Ground Fault Locator is the new model which is developed to fast detect, trace and pinpoint virtual ground faults in LIVE DC systems where electrical cables have breakage with current lost to ground.
-
product
Earth Ground Meters
The earth tester determines ground resistance for both specific and ohm resistances. The earth tester is powered by batteries and have a clock timer function (3 minutes), Data-Hold function, a 3 ½ positions LCD display and their dimensions are 163 x 100 x 50 mm. Resistance ranges come from 20, 200 to 2000 ohms. They have a resolution of 10 / 100 mΩ / 1 Ω. The earth tester measure resistance by means of a constant reverse current (approx. 800 Hz, 2 mA). To measure ground voltage a rectifier is used (5 kΩ/V aprox. 40...500 Hz). The earth tester PKT-2630 series have a small format as well as multiple functions.
-
product
Earth Ground Tester
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.