Filter Results By:
Products
Applications
Manufacturers
Radiation
The transmission of energy through material or space.
- LBA Group, Inc
product
RF Architectural Shielding Products
EMI (Electromagnetic Interference) is often used interchangeably with RFI (Radio Frequency Interference). However, EMI can be any frequency of electromagnetic noise, whereas RFI is a relatively narrow range of electromagnetic noise on the EM spectrum. EMI Shielding can be used to mitigate electric and magnetic radiation across various spaces. Radio Frequency (RF) Shielding can be used to mitigate RFI with specifically designed enclosures that can block RFI. As well, RF Shielding can include application of RF Shielding paints, fabrics, and other materials.
-
product
Personal Safety EMF Measuring Equipment
EME (electromagnetic energy) RF Exposimeter / Personal monitors, worn on the person. The devices monitor the electromagnetic fields and warn of excessive field strengths, e.g. when working on industrial equipment, broadcasting or mobile phone stations, radar installations or other sources of electromagnetic radiation.
-
product
Gamma Radiation Detector
PocketGeiger
Yaguchi Denshi Kogyo Co., Ltd.
Pocket Geiger is a smartphone-connected radiation detector. We have three product types on PocketGeiger series to support various devices you have.; iOS, USB and Embedded ( for ARDUINO, PIC, Edison).
-
product
Radiation Resistant Resolver
Computer Conversions Corporation
Computer Conversions GT Transducers are brushless, Electromagnetic, Rotary Sensors used to provide Precise Absolute or Incremental Position, and Velocity feedback in harsh environments. All Computer Conversions Transducers are continuous rotation, bidirectional, and electronically passive devices (no electronic components to degrade or fail), that require zero maintenance, and may be installed in virtually inaccessible locations.
-
product
Pyranometer
SR15-A1
Hukseflux Thermal Sensors B.V.
SR15-A1 is a high-accuracy solar radiation sensor. It is” First Class” according to the ISO 9060:1990 standard and “Spectrally Flat Class B” in the 2018 revision. With its on-board heater, it is compliant in its standard configuration with the requirements for “Class B” PV monitoring systems of the new IEC 61724-1:2017 standard. SR15-A1 measures the solar radiation received by a plane surface from a 180 o field of view angle.
-
product
Intelligent Detection Units
Measurement of the ambient dose rate equivalent of continuous and average dose rate of pulsed X-ray and gamma radiation in an extremely wide range in harsh operating conditions.
-
product
Solar Energy, PV Monitoring
Apogee silicon-cell pyranometers feature a monocrystalline silicon-cell detector that has the same spectral response as a PV module. The sensors quantify shortwave radiation being harnessed as electricity.
-
product
Radiation Detectors
High Purity Germanium (HPGe) DetectorsSilicon Charged Particle DetectorsScintillation DetectorsORTEC is a leading supplier of solid-state, high resolution, semiconductor radiation detectors. These radiation detectors are used in research, commercial industry, environmental protection, health and medical physics, as well as homeland security to detect gamma-rays, X-rays, and charged particles.
-
product
Multifunction Voltage Tester
*Detects AC voltage by non-contact method: 70VAC to 250VAC*Finds broken wire location*Wrong connection check*Ground / Earthing disconnection check*Detects static radiation of TV / monitor*Checks operating condition of ionizer*Microwave leakage detection: ≥5mw/cm2
-
product
Electromagnetic Radiation Tester
Model KM 196
Kusam Electrical Industries Limited
• Unit : Electric Field : V/m; Magnetic Field : mT• Precision : Electric Field : 1V/m; Magnetic Field : 0.01 mT• Range : Electric Field : 1V/m ~ 1999V/m.• Magnetic Field : 0.01 mT ~ 19.99 mT• Alarm Threshold : Electric Field : 40V/m, Magnetic Field : 0.4 mT• Reading Display : 3½ Digit Digital LCD display with Backlight.• Frequency Range : 5Hz ~ 3500MHZ• Sampling Time : About 0.4 second.• Measuring Mode : Dual Mode• Overload Alert : “1” appears on LCD• Sound & Light Alarm• Data Hold function.• Auto Power Off.• Average & Peak measurement.• Low Battery Indication.• Operating Temperature & Humidity : 0°C ~ 50°C; below 80%RH.• Power battery : 9V Battery.• Dimension : 63.6 x 31 x 125.8mm• Weight : Approx. 146g.
-
product
Calibration Standards
Traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection.
-
product
Fiber Optic Sensors
Leuze electronic GmbH + Co. KG
Plastic fiber optics are suitable for universal applications with low space requirements for object detection. Glass fiber optics are used in demanding environmental conditions with high temperatures and are resistant to chemicals. For radiation through foils or applications with high light power, they offer further advantages through the especially low damping. The flexible fiber optics with various head shapes can be integrated in nearly any system design. The detection range is dependent on the fiber optics and amplifiers used. Fiber optics can be used with the throughbeam principle or with scanning function. As a fiber array with multiple light beams, they can be used to detect especially small objects.
-
product
Solar Simulation Systems
Solar simulation systems with global radiation guarantee the simulation of natural sunlight according to CIE20 and CIE85 Table 4. Our portfolio includes components, systems and systems for solar simulation for test benches in the automotive, military, aerospace, railway, photovoltaic, material research and building materials industries. Our plants and systems stand for high reproducibility and precise test results.
-
product
Precision Conical Dipole
PCD 3100
Site validation measurements according to prEN 50147-3 in fully anechoic rooms. Accurate RF radiation safety measurements (e.g. broadcast stations). All purposes of broadband precision field-strength measurements. Frequency range: 30 MHz - 1 GHz
-
product
NR01 net radiometer
Hukseflux Thermal Sensors B.V.
NR01 is a market leading 4-component net radiation sensor, mostly used in scientific-grade energy balance and surface flux studies. It offers 4 separate measurements of solar and longwave radiation, facing both up and down. NR01 owes its popularity to its excellent price / performance ratio and major improvements relative to comparable instruments. These advantages include weight, ease of levelling, solar offsets in the longwave measurement and pyrgeometer heating, reducing measurement errors caused by dew deposition.
-
product
Portable heat flux sensor, with read-out unit
HF03 / LI19
Hukseflux Thermal Sensors B.V.
The HF03 is a heat flux sensor that can be used in mobile applications. It is combined with LI19, a high accuracy hand-held read-out unit that can be used both for mobile measurements and as an amplifier directly connected to a PC. The combination HF03 / LI19 is typically used to study heat flux levels around flares and fires, and to calibrate flare radiation monitors / flare heat flux sensors.
-
product
Car-to-X Signal Strength Emulator
Qosmotec Software Solutions GmbH
QPER-C2X is a special adaptation of the signal strength emulator QPER, designed for mobile and Vehicular Ad-hoc Networks (MANet and VANet). Every radio devices in such an infrastructure-less network acts as a sender, receiver, and forwarder (router). Therefore, the ports of the QPER-C2X hardware are fully connected with each other by dynamically controllable attenuators. The system is fully designed for frequencies up to 6 GHz, since wireless communication for Intelligent Transport Systems (ITS) is based on the WLAN standard IEE 802.11p from 5.850 MHz to 5.925 MHz. The connected ITS stations can be either on-board units, as they are built into cars, or road side units that are used by road infrastructure (traffic lights, road work area delimiters, velocity signs). For tests in the lab, radio modules of such ITS stations are each kept in a shielding box that prevents any unwanted radiation over the air.
-
product
Turned Log Peri Antenna
MOLP80-1000M
This is Antenna for IEC61000-4-3 Radiation Immunity Test. Unique Structure with turned Element increase the GAIN at the low frequency. Stew structure of 22 and can be fitted to normal Antenna MAST.
-
product
Blackbody System
IR-508/301
Infrared Systems Development Corp.
The IR-508 blackbody reference source is designed to provide infrared radiation as an ideal blackbody emitter. The output energy from the 0.25" cavity closely follows the theoretical maximum energy curve described by Max Planck's equation, and allows users to calibrate, align, and measure infrared devices and phenomena of all types.
-
product
Environmental Radiation Monitoring Systems
With the autonomous radiation monitoring probe GammaTRACER, the gamma radiation dose is continually registered in the chosen time sequence. Energy-saving chip technology allows maintenance-free non-stop operation of the GammaTRACER probe of typically five years, with extended battery pack up to ten years! Hermetically sealed, it is designed to endure the harshest environments.
-
product
Data Panel
IТ-09
Display of measurement results of ambient dose equivalent rate(DER) of gamma radiation obtained from the BDBG-09 detecting unit of gamma radiation.
-
product
Xenotest
440
Atlas Material Testing Technology
The Xenotest 440 is a highly versatile xenon weathering instrument for a variety of materials. Designed for fast and economical testing, the Xenotest 440 utilizes XenoLogic™, a revolutionary new twin-lamp operating technology which enables high irradiance levels of 120 W/m2 of total UV radiation.
-
product
Application Software
Application software is a key element of a premium measurement system. Applying this software approach to a broad range of radiation detector hardware and data acquisition systems, ORTEC software offers comprehensive nuclear measurement solutions that provide integrated hardware control, analysis, and display in a single, easy-to-use package.
-
product
Orotron (High-Power BWO) Based Sources 120 To 370 GHz
Insight Product Company offers Orotron based sources of radiation at frequencies 120 to 370 GHz. The Oroton tube is installed inside the permanent magnet and does not require any adjustment by the customer. The Orotron sources are wide-banded, small in size, very reliable, powerful, and easy to operate. We offer phase-locking as an option on our Orotron based sources to maximize the phase and frequency stability.
-
product
Radiometric Probe for Photons Flow
LPPAR03… Series
The probe LPPAR03 measures the ratio between the number of photons that strike a surface in one second, in the 400 nm…700 nm spectral range and the surface area (m²). This quantity is defined as PAR: Photo-synthetically Active Radiation.
-
product
Radon Professional Monitoring
Our dedicated range of products and accessories has been especially designed to fit these needs and to provide accuracy in the following application fields: Short and long-term monitoring of radon concentration indoor and outdoor, water and soil gas analysis Radon surveillance and mitigation at workplaces (according to valid radiation protection regulations) Geological survey, e.g. vulcano watching, earthquake surveillanceAlphaGUARD products reputation is worldwide recognized, as a reference device for calibration for active and passive radon detectors.
-
product
Analog Ionizing Radiation Detectors
A great general purpose analog radiation detector. Detects from 0-50 mR/hr.
-
product
Flame Sensor Signal Processor
SPECTRA Pro
The SPECTRA PRO's frequency discrimination feature allows it to filter out background radiation from hot, glowing boiler walls and also radiation interference from neighboring burners or pilots. This discrimination capability ensures that when a flame is extinguished, the relay trips immediately because there are no background radiation effects that could provide a false flame on condition.
-
product
3 AXIS DIGITAL ELF 50/60Hz AC GAUSSMETER, FWBELL
4100 Series
Integrity Design and Reseach Corp.
Typical Applications include checking the 50 and 60 Hz magnetic fields (EMF) produced by equipments such as AC Power Lines, Office Equipment, Video Display Terminals, Household Appliances, home and Building Inspection, etc.. Magnetic fields are invisible radiations, the best method to measure the strength fields is to use one of the accurate gauss meters offer by Integrity Design & Research corp.
-
product
Spot Pyrometers
Fluke Process Instruments spot pyrometers are designed to be flexible and easy-to-install; durable to withstand the most demanding harsh industrial environments; and visual so you can see and understand your process temperature data. Spot pyrometers are a type of fixed thermal sensor used for measuring a single point on high-temperature surfaces, often in large furnaces or kilns. These devices measure temperature from the thermal radiation emitted, also known as radiometry.
-
product
Digital Spectroscopy
CAEN SyS is the new Systems & Spectroscopy Division of CAEN Spa. Such Division relies upon an extremely strong foundational knowledge of nuclear measurement instrumentation in developing Radiation Measurements Systems and Spectroscopy Solutions. These systems and solutions are perfectly suited to operations involving Nuclear Fuel Facilities, Nuclear Power Plants, Measurements Laboratories, and Security Applications.