Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
20-Pin GMCT Cable, Female to Unterminated, Tinned Ends, 10A, 0.5m
A020GFR-T-0C050
The 20-Pin GMCT cable assembly is constructed from 19/0.254 (18AWG) Tinned Copper Wire with PFA insulation. Screwlocks are provided to secure the connector to associated product. The unterminated connections are coded to match the connector pin designation. Users may need to make their own cable strain relief arrangements when using this product and should ensure appropriate electrical safety precautions are observed.
-
product
Measurement
Strain Gauge Meter
The program Strain gauge meter is intended for various strain gauge measurements with the use of strain gauge transducers (e.g., force and torque transducers, RPM sensors, bridge and half-bridge circuits based on strain gauges, etc.) and a measurement module for strain gauges ZET 017-T.
-
product
Extensometers
Extensometers measure strain, the change in length of a specimen divided by the original length (gauge length) of the specimen. Tinius Olsen offers wide range of extensometers based on your testing needs including video, optical and physical contact with specimen.
-
product
Submersible Extensometers
Model 4030
Jinan Testing Equipment IE Corporation
The Model 4030 extensometer uses a special LVDT-like sensor to measure strains on samples submersed in water or other compatible liquids. The unit is provided with the signal conditioning electronics. The extensometer is a semi-custom design, which is available in smaller measuring ranges up to 5 mm (0.2 inches). Clip-on (COD) style designs are also available.
-
product
Vibrating Wire Peripherals
Many Campbell Scientific vibrating-wire peripherals enable dataloggers to read vibrating-wire sensors (also known as vibrating-wire or vibrating-strip transducers). These sensors measure strain, load, pressure, and water level, and they output a frequency signal generated by a vibrating filament. Campbell Scientific also offers vibrating-wire dataloggers that read the sensors directly.
-
product
Bi-Axial or Axial Averaging Extensometers
Model 3560
Jinan Testing Equipment IE Corporation
This extensometer is ideally suited for testing anisotropic materials such as advanced composites as well as for general purpose tests like determining Poisson’s ratio. The Model 3560BIA uses a design unique to Epsilon, where the knife edges remain parallel during the displacement. This approach greatly reduces crosstalk between axes and allows use on round or flat specimens with equal ease. These extensometers are very easy to mount. Integral springs hold the unit on the test sample. The parallel multiple flexure design makes these units very durable.The Model 3560AVG reads axial strain only as a single averaged output. It may also be supplied with two independent outputs, one measurement from each side of the specimen. This set-up is most commonly required when an indication of specimen bending is desired. The second version, the Model 3560BIA, includes both the averaged axial strain and the transverse strain. Again, this may also be configured as dual independent axial readings, which results in a three channel extensometer.The Model 3560 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
20-Pin GMCT Female Connector, 10A, Without Backshell
92-960-020-10A-F
This accessory is designed to allow users to directly terminate a cable with soldered connections to the connector. It is supplied with removable solder bucket contacts suitable for wires up to 16 AWG. When the product is used without a backshell users should make their own cable strain relief arrangements and ensure appropriate electrical safety precautions are observed.
-
product
Cable Assembly 15-Pin D-Type, Female to Unterminated With Ferrules, 2m
40-972-015-2m-FU
The 15-Pin Connector to Unterminated Cable Assy is constructed from PFA insulated 19/0.18 (21AWG) Tinned Copper Wire. The connector can be secured to the associated product by screwlocks. The unterminated connections are coded to match the connector pin designation and include crimped on ferrules to ensure the wire strands cannot break when they are terminated. When using this product additional cable strain relief arrangements may be necessary and appropriate electrical safety precautions should be observed.
-
product
Strain Gauges
Available in a variety of models to cover most strain measurement applications. Rugged construction and flexibility make them suitable for highly accurate static and dynamic measurement.
-
product
Displacement Transducers
Procter & Chester Measurements Ltd
Pressure: Measures gas or liquid pressure. Pressure is an expression of the force required to stop a fluid from expanding. The transducer generates a signal from the pressure imposed upon it. Torque: Measures the torque (or twisting motion) on a static or rotating system. The static torque element has little movement and therefore more economic to manufacture and purchase. Rotary or dynamic torque is more complicated as the signal needs to be transferred using slip rings, wireless telemetry or rotary transformers/inductance technology so that the strain gauged shaft can continuously rotate. Displacement: Measures distance. The displacement transducers that PCM offer are slightly different to standard units. They have a strain gauge/wheatstone bridge. The benefit here is that if the customer has existing electronics that uses strain gauge/load cell technology, they can use them with these sensors.
-
product
Receiver, I1, With Protective Cover
310128101
i1 accepts a single iCon module and allows a variety of signal, power and coaxial connections. A protective cover is included with the receiver. Other accessories, such as keying pin kits and strain relief, are available.
-
product
20-Pin GMCT Cable, Male to Unterminated, Cut Ends, 10A, 0.5m
A020GMR-C-0C050
The 20-Pin GMCT cable assembly is constructed from 19/0.254 (18AWG) Tinned Copper Wire with PFA insulation. Screwlocks are provided to secure the connector to associated product. The unterminated connections are coded to match the connector pin designation. Users may need to make their own cable strain relief arrangements when using this product and should ensure appropriate electrical safety precautions are observed.
-
product
Mobile Test Devices
burster präzisionsmeßtechnik gmbh
Device test, strain gauge simulator, sensor test, reference measurement chain
-
product
Strain gauge
RF9 Miniature Rosette
Thanks to its three stacked measuring grids, the miniature SG rosette RF9 is only 5 mm in size. Its small diameter enables it to determine a biaxial stress state with unknown principal stress direction in the most confined space. The SG rosette is therefore particularly suitable for measurements on electric circuit boards or especially small components.
-
product
Torque Measurement Trainer Module
Unitech Scales And Measurements Pvt. Ltd
Torque Measurement Trainer comprises of strain gauge based reaction type torque transducer, fulcrum arm of 1 M length with L angle to mount the sensor, Pan & weights with digital torque indicator to read the torque in Kg-m.
-
product
S-Type Load Cells
S-Type load cells are low-cost and high performance side mounted load cells suitable for a number of weighing and general force measurement applications. They come with a 6-foot strain relieved integral cable with pigtail leads that are stripped and tinned for electrical interface.
-
product
Rheology
Rheology is the study of flow and deformation of materials. Deformation and flow are referred to as strain or strain rate, respectively, and indicate the distance over which a body moves under the influence of an external force, or stress. For this reason, rheology is also considered to be the study of stress-strain relationships in materials.
-
product
Cable Assembly 15-Pin D-Type, Male to Unterminated With Ferrules, 2m
40-972-015-2m-MU
The 15-Pin Connector to Unterminated Cable Assy is constructed from PFA insulated 19/0.18 (21AWG) Tinned Copper Wire. The connector can be secured to the associated product by screwlocks.The unterminated connections are coded to match the connector pin designation and include crimped on ferrules to ensure the wire strands cannot break when they are terminated. When using this product additional cable strain relief arrangements may be necessary and appropriate electrical safety precautions should be observed.
-
product
Fatigue Failure Tester
EKT-2002FF
EKT-2002FF Flexing Fatigue Tester is designed in accordance with ASTM D4482 to test the fatigue life under a tensile strain cycle on different kinds of vulcanized rubber compound to determine the fatigue life at various extension ratios.
-
product
C Series Universal Analog Input Module
The C Series Universal Analog Input Module helps you perform multi-purpose measurements. This module includes built-in support for accelerometer, powered sensor, full-bridge, and voltage measurements as well as quarter-bridge, half-bridge, 60 V, and current measurements using measurement-specific adapters. You also can choose options to measure signals from sensors such as strain gages, resistance temperature detectors (RTDs), thermocouples, load cells, and other powered sensors.The C Series Universal Analog Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.
-
product
Terminal Test Kit (19 PCS)
3605
Peaceful Thriving Enterprise Co Ltd
1. Check high and low voltages (power and ground) on 6, 12 and 24V system.2. 4mm connection for banana plugs.3. LED indicates red for power (high) and green for ground (low).4. High impedance protects sensitive electronic ignition components.5. Connects red lead to power source and black lead to ground source.6. 1.8m long heavy-duty dual leads with battery clips and spring strain relief.7. Facilities the measurement on connectors and components without destroying the insulation or the plug connection.
-
product
68-Pin SCSI Micro-D M to 2x34 2m
40-971-068-2m-MF
The 68-Pin SCSI Style Micro-D Cable Assembly is constructed from 2x34-Pin Twisted Pair cable with PVC insulation, terminating with 2x34-Pin polarised IDC connectors. Strain relief is provided via a metal spring latch on the 68-Pin connector.
-
product
Rectal Probe For Rats (Isolated)
RET-2 ISO
• An isolated sensor (can be used with monitoring equipment where electrical interference from other electrodes may be present).• Reinforced strain relief for applications where probe is in more frequent use.• Smooth ball tip. Stainless steel shaft - '' long, .059'' diameter. Tip diameter .125'', 5 foot lead length. Time constant 0.8 seconds.
-
product
High-Temperature Zeus PEEK FBG Cable Sensor
Technica Optical Components, LLC
The T150 is a ruggedized high temperature non-metallic cable sensor designed for monitoring distributed temperatures and strains in environments to 260 Degrees Celsius with submillisecond response time. High temperature resistant non-metallic sensor. Ideally suited for applications where there is concern that the high temperature or chemical composition of the surrounding environment will cause damage to the sensors.
-
product
Extensometers for Indirect Tensile Testing of Asphalt
Model 3911
Jinan Testing Equipment IE Corporation
For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Stress Analysis Strain Gauge
Structures can, and do, break, and this may be important and sometimes dramatic. It’s critical to determine whether a particular object made from a particular material can carry a particular load. If a true stress is ignored, the cost of not acting is usually far higher than the cost of dealing with the problem earlier. A well-done strain measurement will produce an accurate representation of the strain actually present under the sensor. Strain data, however, is seldom gathered as a means unto itself. It is usually little more than a convenient vehicle for indirectly obtaining information about some other engineering parameter.
-
product
Averaging Clip-on Extensometer
The Instron 2650 Series Biaxial Extensometers are ideally suited for testing a wide range of materials, including polymer matrix composites, metals, and plastics over a range of temperatures. Two sensors measure axial strain on opposite sides of the specimen. Versions are available which provide either a single averaged axial output or 2 independent axial outputs. The extensometers meet the calibration requirements of ASTM E83 class B1, ISO 9513 class 0.5, and ISO 527.
-
product
Transverse (Diametral) Extensometers
Model 3575
Jinan Testing Equipment IE Corporation
Designed for general purpose transverse or diametral strain measurement on axially loaded specimens. This model may be used simultaneously with the model 3542 axial extensometer.
-
product
Static Soil Tester
GEO-probe
The complex is implemented on the basis of a portable computer and the CompactRIO control and measuring system. The software for recording and displaying measured signals and control of measuring equipment is developed on LabVIEW. The second modification of the measuring system includes, developed by our company, a miniature digital measuring module of a strain gage with a built-in ADC and inclinometer and a USB interface for connecting the digital measuring module of the probe to the computer.
-
product
PXIe-4331, 102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module
781345-01
102.4 kS/s, 24-Bit, 8-Channel PXI Strain/Bridge Input Module—The PXIe‑4331 is a high-speed input module that provides integrated data acquisition and signal conditioning for dynamic strain, load, and pressure measurements. This module includes increased accuracy, high data throughput, and synchronization features, making it ideal for high-density measurement systems. To remove noise, the PXIe‑4331 offers antialiasing and digital filters per channel. Each channel also features an independent, programmable excitation voltage. Additionally, the PXIe‑4331 provides remote sensing, internal bridge completion, and shunt calibration options per channel.