Filter Results By:
Products
Applications
Manufacturers
Test Cases
sets of events to find the performance boundaries of a design.
- Taylor Dynamometer, Inc.
product
300 HP Complete Bench Hydraulic Test Center
HTC-300
The Hydraulic Test Center (HTC) is a versatile machine designed to test heavy-duty, off-highway hydraulic components. The 300 hp (224 kW) HTC Complete Bench is for the dealer that services components from a predominately medium size machine mix such as large construction equipment (loaders, dozers, excavators). The Complete Bench offers full functionality to test all types of pumps and motors including: transmissions, hydraulic motors, hydraulic cylinders, valve blocks, torque converters, open and closed loop pumps.
-
product
White Box Testing
Does your application have legacy code and your software code messy? If the answer to the above questions is ‘Yes’, your application will fail to perform as expected. Under such cases, you need to optimize the internal structure of your application so that it performs well. To test for the errors in the internal structure opt for white-box testing.
-
product
Three-Phase Transformer Demagnetizer
DEM60C
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
product
8 Deluxe Noid Light / 2 IAC Kit Plus One Fiber Optic Noid Light Extension
3621
Peaceful Thriving Enterprise Co Ltd
*Kit packs in a deluxe molded plastic case.*Set includes: 8 Noid lights for testing GM PFI, FORD TBI, GEO TBI, BOSCH PFI, GM TBI, GM SCPI, GM MULTEC 2 and BOSCH 2.*One IAC signal test lights for GM TBI and PFI fuel injection system, and one for GM Model 1987 or newer GM Model 700 TBI and PFI fuel injection system. Plus one fiber optic Noid Light extension.
-
product
Bi-Axial or Axial Averaging Extensometers
Model 3560
Jinan Testing Equipment IE Corporation
This extensometer is ideally suited for testing anisotropic materials such as advanced composites as well as for general purpose tests like determining Poisson’s ratio. The Model 3560BIA uses a design unique to Epsilon, where the knife edges remain parallel during the displacement. This approach greatly reduces crosstalk between axes and allows use on round or flat specimens with equal ease. These extensometers are very easy to mount. Integral springs hold the unit on the test sample. The parallel multiple flexure design makes these units very durable.The Model 3560AVG reads axial strain only as a single averaged output. It may also be supplied with two independent outputs, one measurement from each side of the specimen. This set-up is most commonly required when an indication of specimen bending is desired. The second version, the Model 3560BIA, includes both the averaged axial strain and the transverse strain. Again, this may also be configured as dual independent axial readings, which results in a three channel extensometer.The Model 3560 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
PCI Express 5.0 Protocol Exerciser/Analyzer
Summit Z58
The Summit Z58 is a PCIe 5.0 protocol traffic generation test tool used for critical test and verification intended to assist engineers in developing and improving the reliability of their systems. The Summit Z58 can emulate PCI Express 5.0 root complexes or device endpoints, allowing new designs to be tested against corner case issues.
-
product
RDM Responder Tests
The RDM Responder Tests are an automated testing suite for RDM Responders. Testing RDM Responses previously involved connecting an RDM Controller and sending commands to the responder, verifying the behavior matched what was expected. This can be a time consuming process and many of the corner cases aren't exercised.
-
product
Transmission Line Pulse Testing
Transmission Line Pulse testing, or TLP testing, is a method for semiconductor characterization of Electrostatic Discharge (ESD) protection structures. In the Transmission Line Pulse test, high current pulses are applied to the pin under test (PUT) at successively higher levels through a coaxial cable of specified length. The applied pulses are of a current amplitude and duration representative of the Human Body Model (HBM) event (or a Charged Device Model – CDM – event in the case of Very Fast TLP, or VF-TLP).
-
product
Premium Automotive DMM
597IR
*Highest Quality Auto-Ranging DMM Designed for Automotive Trouble Shooting *18 Test Functions, 48 Test Ranges *Peak Min/Max records transient voltages as fast as 1 millisecond *Min/Max Mode records variations in all functions *Exclusive Non-Contact IR Thermometer Adapter Included - 1022F/550C max temp readings *Also measures Temperature via Temp Probe in Both F and C *Milliseconds Pulse Width Measures Fuel Injector ON-TIME *Inductive RPM Readings for both DIS and Conventional Ignitions *Desirable 20 Amp Test Range - Dual Fuse Protection *Modern Design, the Protective Holster is Built Into the Housing *Data Hold, Auto Power-Off, + Trigger Adjust *Large LCD Display w/White LED Backlighting and 40 Segment Analog Bargraph *Blow Mold Case, Test Leads, IR Thermometer Adapter, K-Type Temp Probe, Inductive RPM Clamp and Instructions included
-
product
Wireless Device Functional Test Reference Solution
The Keysight S8890A Wireless Device Functional Test Reference Solution provides an automation environment which is both simple to use, yet comprehensive and powerful. Based on the Test Automation Platform www.keysight.com/find/TAP, S8890A provides optional instrument driver/plug-ins offering simplified logically grouped control steps. These steps can be sequenced, looped and swept to provide powerful individual test cases or comprehensive sequences. Each driver/plug-in is provided with extensive starter sample test cases which can be modified by Keysight or the end user the UE to be tested. Plug-in options:
-
product
Relay Test Jumper Kit
56810
Set includes four jumpers to fit the most popular size relays on domestic and import vehicles. Simply remove relay to be tested, insert correct jumper and insert relay into jumper. When using green four pin jumper be careful to align pins on jumper and relay correctly. No need to pierce wires or connect multiple jumper wires. Jumpers have tabs for clamping and flat pads to place test leads on. Set comes in blow-molded case for storage.
-
product
Junior Set and Kits
Contents* AM-510-EUR (Digital multimeter)* ACD-10 PLUS (Digital current clamp)* TPP1-C1 (contact thermometer)* EU-200 (test lead set with 2 leads), 2 test prods (4 mm), 2 crocodile clips (CAT III/1000 V)* Hard carrying case
-
product
Pitot Static Tester
ADSE 643
The ADSE 643 caters fully for all aircraft types and the different electrical power supplies.It can be used for testing high performance civil and military aircraft, fixed and rotary wing.This Pitot Static tester is designed primarily for flightline use to cover the testing of all barometric and manometric pressure instrument systems.The ease of use and portability enables all checks to be carried out easily on the flight deck or in the cockpit, by a single operator.The test set is housed in an anodized metal and rugged case.An attached case contains the pressure hoses and electrical cables.
-
product
Integrated Test Case Management System
TestLog
TestLog is an integrated test case management system. It provides a tool for software test teams and engineering companies to create and update effective test cases. TestLog has been designed with versatility in mind and should plug seamlessly into any testing methodology.
-
product
Mini Automatic Transformer Observation System
mini-ATOS
The mini-ATOS, is a professional multifunctional power transformer and substation diagnostic system. This compact and intelligent instrument can perform many routine and advanced tests such as Winding Resistance (WR), Dynamic Resistance Measurement (DRM), Turns Ratio (TR), Frequency Response of Stray Losses (FRSL), Magnetic Balance, and other diagnostic parameters. With the built-in fully automatic multiplexer, only a one-time connection is required for nearly all functions, which saves a considerable amount of time. The portable, rugged case is perfect for use anywhere onsite or in a laboratory. It is specially designed for fast and easy measurements with the well-known high precision and quality of all Raytech instruments.
-
product
Extensometers for Indirect Tensile Testing of Asphalt
Model 3911
Jinan Testing Equipment IE Corporation
For indirect tensile testing, such as for resilient modulus, these extensometers measure the lateral deformation of specimens. They are self-supporting on the sample and clip on in seconds. The traditional way this deformation has been measured was prone to errors caused by slight rocking of the sample as it is loaded. The self-supporting design of the Model 3911 eliminates this problem. This unit will handle the dynamic pulse requirements of resilient modulus testing.The speed of mounting makes test set-up much faster than with the older method. The pivot mounting used ensures that the specimen contact pads meet the often uneven asphalt surface as well as possible. The measuring range options available allow a wide range of testing, yet can easily measure the sometimes very small displacements required.The Model 3911 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Auto-Ranging Digital Clamp Meter
DCM401
Expert Quality, auto and manual ranging clamp meter capable of voltage, current, resistance, diode, continuity, capacitance, frequency, duty cycle and temperature testing. Maximum jaw - opening diameter of 36mm, backlit LCD screen, auto power off and a useful inspection light. Supplied with test leads, temp probe, case and 3 x AAA batteries.
-
product
Analog Clamp Meter
Operation0C~ 40C(32~104)/<80% R.H.(no condensation) Storage-10C~ 50C(14~122)/<70%R.H.(no condensation) Dimension & Weight 243(L)x91(W)x45(H)mm Approx.360g (Including battery) Accessories Battery UM-3 (AA) 1.5V x1 Instruction Manual x1 Test Lead (red + black) x 1 Carrying case x1 Optional Accessories Temp. Probe (NR-81) AC Line Splitter(DE-10ALS) *Applicable to electrical appliances small current
-
product
Solar Array Simulator
Among other things, solar array simulators are required for testing satellite power supplies. An SAS (Solar Array Simulator), consisting of an interconnection of several Solar Array Simulator modules, maps the solar panels and displays the individual strings connected in parallel. Optionally, the individual SAS modules are monitored by a Second Level Protection, so that the test object is not damaged in case of errors with the voltage sources. Additional circuitry is implemented via project-specific test modules. The signal path to the DUT can be separated, e.g. for dynamic current measurements.The Keysight Solar Array Simulators used were specially developed for satellite applications and cover the significantly higher requirements regarding the control speed of MPP tracking compared to terrestrial applications.
-
product
Ingress Protection: Dust Protected and Dust Tight (IP5X & IP6X)
Ingress protection testing tests the level of protection an enclosure provides against intrusions. Two such sets of ingress protection tests involve exposing the equipment under test (EUT), to dust. These tests are numbered IP5X and IP6X. The first digit, in the case of dust protected, would always be a 5, and in the case of dust tight, would always be a 6. The first digit, represented by the “X”, ranges from 0 to 9 and specifies the protection from liquid.
-
product
Circuit Breaker Timer Kit
CBT-Eco
*Input Supply: 230 V ± 10 %, AC, 50 Hz, 1 Phase (Ground must).*Display: 16 X 2 Big size LCD display with backlight.*Accuracy : Class 0.5*Resolution: 1 milli second*Count: 1 to 9999 milli second*Operation: Accurate Measurement for Close and Trip Command for BreakersThrough Trip-Free Operation C-O-C timing can be measure accurately.Up to 99 No. of Bounces for Close Operation on all three Pole can be count.(Model: CBT CP)Measure timing up to 7 numbers of Bounces on all pole.(Model: CBT CP)Reset for Next Measurement.Indicate the Status of Pole (Close /Open) during start of Test on LCD Display.*Front Panel : Operation Guide Sticker Plate, and Connectors. .(with Printer on Model: CBT CP*)Housing : Aluminum Carrying Case Enclosure.*Accessories : Mains Power Cable, Probe set of 5 MTR long, computer Interface cable for connecting with PC or Laptop and Bag. (Optional), User’s Manual and Test Report.*AVAILABLE MODEL:· Model: CBT CP, with PC Interface and software.· Model: CBT P, without PC Interface and without Software.
-
product
Test Case Creation
This is the initial phase where we collect and analyze the requirements from a testing point of view and identify the testable requirements. Our dedicated QA team may interact with various stakeholders (Client, Business Analyst, Technical Leads, System Architects etc) to understand the requirements in detail. Requirements could be either Functional (defining what the software must do) or Non-Functional defining system performance/security availability.
-
product
E-Z Check® Circuit Tester
61-035
*Tests for correct wiring, open ground, reverse polarity, open hot, open neutral, hot on neutral, hot and ground reversed with open hot in 3 wire, 120 VAC circuits*Simulates ground fault for testing GFCIs*No-slip ergonomic design maximizes comfort*Premium neon lamps prevent false readings*Tough, impact-resistant case*2-year warranty
-
product
Battery Portable Passive Intermodulation Analyzer
iPA Series
The iPA Series Passive Intermodulation (PIM) analyzer is the first battery powered PIM Test Analyzer versatile enough to support multiple test scenarios such as testing at the top of the tower, base of tower, roof top and in-building for DAS systems. This IEC compliant 20W, rugged, battery operated design includes a tablet computer in a ruggedized case for remote control. This allows hands-free dynamic testing that is safe and convenient. Add the optional Range to Fault (RTF) module to quickly identify the location of PIM and Return Loss sources.
-
product
High Temperature, Low Strain, Extended Performance Capacitive Extensometers
Model 7650A
Jinan Testing Equipment IE Corporation
Model 7650A extensometers measure strains with extremely high precision due to their design features and low strain range. All models are capable of tension and compression strain measurement, and may be used for fatigue testing under fully reversed load and strain conditions at frequencies up to 10 Hz.All 7650A models mount rigidly on the load frame and incorporate slide mounting to bring the extensometer into contact with the specimen. The gauge length is set automatically before mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.These units are specifically designed to provide high accuracy, high resolution measurements and perform high temperature fatigue testing at the highest possible frequencies. They incorporate capacitive sensors for low operating force and include electronics with programmable filtering and multi-point linearization for improved performance and accuracy. The overall design minimizes, and in many cases virtually eliminates, any influence from common lab environment vibrations.These water-cooled extensometers are equipped with high purity alumina rods for specimen contact when testing to 1200℃ (2200°F). Silicon carbide rods are used for the 1600℃ (2900°F) high temperature option.The Model 7650A is often customized for specific test needs. Contact Epsilon for a configuration that matches your requirement.
-
product
Boundary Scan Test (BST)
In the simplest case, the BST can be carried out via the connector of a module.Digital components require a JTAG port. In direct comparison to the ICT, the BST requires longer test times and the testing of analog components is not possible.
-
product
Test Management App
Test Management goes mobile with the new Kualitee App. Now, simply use your Kualitee mobile app to manage your testing activities by viewing multiple projects, creating defects, approve or reject test cases and view your Kualitee Dashboard to get the latest status reports on the defects being reported.
-
product
XRF
O Series
The O Series combines high performance with a small x-ray spot size. This is made possible by the poly-capillary focusing optics system that replaces the collimator assembly installed in standard Bowman systems. The optics are designed to focus the x-rays coming from the tube exit window to a very small spot size (80μm FWHM) while retaining virtually 100% of the tube flux. So instead of attenuating the x-rays that can’t fit through the small apertures, as is the case with collimator systems, the poly-capillary optics assembly allows almost all of the x-rays from the tube to reach the sample. The result is much greater sensitivity for testing very small components or thin coatings. Shorter test times can achieve even better repeatability when comparing optics systems vs. a similar sized collimator.
-
product
Portable Hardness Tester
PHT-1700
Loaded with features, this economically priced hardness tester is capable of measuring the surface hardness of a broad variety of metals on flat and round surfaces. This instrument comes complete with the universal D impact device, calibrated test block and rugged carry case.
-
product
Field Test Kit
621
TESCO’s light-weight, 50 Amp Field Meter Test Kit (Catalog No. 621) with Power Factor, has been designed to reduce the weight of field test equipment to the lowest possible limit. The carrying case is fabricated from durable powder coated aluminum. The total weight of the meter test kit including leads, and digital reference standard is only 25 lbs! The test kit also incorporates ample storage space for the cable set.
-
product
Circuit Breaker Analyzers & Timers
CAT Standard Series
Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.