Com-Power Corporation
Com-Power Corporation has been a supplier of instrumentation for EMI / EMC Testing (electromagnetic compatibility), telecommunication ( Part68 ) and product safety ( UL / IEC CSA) testing since 1989.
- 714 528 8800
- (714) 528-1992
- sales@com-power.com
- 114 Olinda Drive
Brea, CA 92823
United States of America
-
product
Log Periodic Antennas
Log Periodic antennas allow quick sweep measurements without a band break. This feature makes it convenient to use the Log Periodic antenna with a automated emissions or immunity measurement system. The size of the antenna also allows it to be used in a small area like a shield room.
-
product
Impedance Stabilization Networks
ISN
They are required for the measurement of conducted common mode noise on Telecom Cables of Information Technology Equipment (ITE). These measurements are necessary to meet the requirements specified in CISPR 22 and CISPR 32 standards.
-
product
CDNs
M Series
Coupling Decoupling Networks are recommenced for all power supplies connections. The distubance signals are coupled to each conductor in the supply lines according to EN 61000-4-6 standard. The standard M series CDNs have a current rating of 25 Amps. Com-Power CDNs are available for power supplies from 1 to 5 conductors. These CDNs cover the frequency range of 150 kHz - 230 MHz.
-
product
Combilog Antenna
AC-220
The AC-220 Combilog antenna is for EMC emission and immunity up to 2 GHz.. It combines the electrical properties of two antenna (biconical and Log ). It reduces overall testing time by 20 - 30% due to antenna switching. It is Optimized for emission measurements, but can handle up to 500 Watt CW, making it suitable for most immunity measurements . Each antenna is individually calibrated at 10 meters and the data included the purchase price.
-
product
Preamplifiers
Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.
-
product
Absorbing Clamps
The absorbing clamps also known as ferrite clamps are used for measuring disturbance power on power input lines as well as other auxiliary I/O lines.
-
product
Antenna Kits
Com-Power offers five portable antenna kits suitable for offsite EMC testing. These kits are supplied with a custom hard plastic carrying case which has individual compartments for all the included items.
-
product
Near Field Probes
A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
product
Telecom Conformance Analyzers
The Telecom Conformance Analyzers are all-in-one conformance testing solutions to worldwide regulatory & industry standards, for many types of telecom equipment ranging from phones, cellular phones including LTE to digital switches, PBXs and VoIP gateways.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
Current Probes
Com-Power's Current Injection Probes are used for RF conducted immunity testing per IEC 61000-4-6, CISPR 16-1-2, RTCA DO-160 and MIL-STD 461. Current injection Probes are to be used only when there is no commercially available CDN for the type of port(s) to be tested.
-
product
Transient Limiters
Transient limiter LIT-153A and LIT-930A protects a spectrum analyzer input from high-level transients from the line impedance stabilization networks during EMC conducted emissions testing. It has a combined frequency range of 9 kHz to 30 MHz. The built in high pass filter helps reduce 50/60 Hz line feed through. (see application notes)
-
product
Line Impedance Stabilization Networks
LISN
LISN stands for 'Line Impedance Stabilization Network'. Com-Power offers a line of LISNs developed for conducted emission testing according to the most commonly adopted EMC specifications like CISPR, FCC, ISO, EN, RTCA DO-160 and MIL-STD 461D. The LISN circuit is designed and constructed to meet the performance criteria given by these standards.
-
product
Biconical Antennas
Biconical antennas are used for emissions and immunity testing to meet various EMC standards specified by FCC, CISPR and EN. The broadband characteristics of the biconical antenna make it a good choice for making sweep measurements and for automated measurement systems.