product
BDV Transformer Oil Test Sets
NMC''s Transformer BDV Oil Test Set is a portable unit as per relevant Indian Standard Specification IS :6792 :1992, suitable for operation on 230 / 240 Volts, A.C. 50 Hz. A three core flexible cable is connected to the unit with three pin socket to connect the mains. The H.V. Transformer is a completely dry, resin encapsulated with two H.V. terminals with mounting saddles. The center point of the transformer is earthed, so that the voltage of each terminal to earth is only half the test voltage.
-
product
Manually Operated Transformer Oil Test Set
We offer Manually operated Transformer Oil Testing Kits to check the DI-electric strength of the insulating Oils as per relevant specifications via. IS 6972. It is a useful equipment for transformer / switchgear manufacturing units. Oil frittering agencies, repair shop and electrical maintenance departments.
-
product
Automatic Transformer Oil Test Set With Printer
Oil Test is an equipment designed to test the dielectric strength of Insulating Oils as per relevant specifications vis. IS 6972. It is a useful equipment for Transformer / Switch Gear manufacturing units. Oil fettering agencies, repair shop and electrical maintenance departments.
-
product
High Voltage Transformers
We, NMC, are engaged in manufacturing AC/DC High Voltage Transformers ranging from 5kv upto 150Kv having current capacity from 10mA to 200mA AC/DC in Air cooled or Oil Cooled type as per the customer requirement.
-
product
Automatic Voltage Regulating Relay- Standard Model
NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.
-
product
Automatic Circuit Breaker Timer Kit With Printer
NMC OFFERS FULLY AUTOMATIC CIRCUIT BREAKER TIMER KIT WITH IN BUILT PRINTER AND COMPUTER INTERFACE.
-
product
Relay Test Set
RNT-5A
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.
-
product
12 Kv Fully Automatic Capacitance Tan Delta Tester With Printer
NMC offer Fully Automatic Capacitance Tan Delta Test Set with Printer and Computer Interface, Range : 0-12kV, Model : CTD-12.
-
product
Fully Automatic Transformer Turns Ratio Tester
DY100
DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.
-
product
AC DC High Voltage Divider
NMC make products are the ideal equipment for HV measuring products are the ideal equipment for HV measuring instruments, apply in power system, electronic equipment factory to test frequency AC high voltage and DC high voltage. This product is composed by HV measuring part and LV display instrument. HV part and LV display instrument are separate when working, it is safe and reliable.
-
product
Standard Tap Position Indicator
NMC,s Tap Position Indicator is a Microprocessor based specially designed instrument used to indicate the Tap Position of the Power Transformer with On Load Tap Changer.
-
product
TPI With 4-20mA Dual Outputs
TX-205
NMC's Digital tap position indicators, Type: TX-205 Are instruments used to indicate the tap position of the power transformers with OLTC. TX-205 Comes With 4-20mA Single / Double output for SCADA systems.
-
product
Sonel Poland Make Digital Insulation Resistance Tester
Mic-5001.
5kV/5TeraOhms, Battery-cum-Mains Operated, Model : Mic-5001.
-
product
Digital Tap Position Indicator With Voltage &Counter Display
NMC''s latest offering digital tap position indicator with voltage and counter display, type: TX-204, is a fully micro controller based instrument used to indicate the tap position of the power transformer also indicating the voltage and counter indications simultaneously at a same time.