IBEKO Power AB
Our goal is to always keep providing the world market with the most advanced test solutions for transformers, circuit breakers and batteries
- +1 800 599 8113
+46 70 0925 000 - +46 8 731 77 99
- sales@dv-power.com
- Box 1346
Lidingö, 181 25
Sweden
-
product
Transformer Test Equipment
DV Power test instruments perform various diagnostic tests on power and instrument transformers. Even more, a unique feature is a condition assessment of on-load tap changers. Performing a transformer test before their breakage can be crucial.Test instruments are portable and enclosed in durable metal cases. Also, the 19” rack-mounted version suitable for factories is available as well.Applications supported by DV Power transformer test equipment include:Winding resistance measurement (IEC 60076-1)Analysis of on-load tap changers (IEC 60214-1)Heat run test (IEC 60076-2)Automatic transformer demagnetizationTurns ratio measurement of power and instrument transformers (IEC 60076-1)Excitation current measurementPhase angle measurementTransformer vector group detectionDemagnetization status verificationAll of the above-mentioned measurements are performed with the highest accuracy.The advanced DV-Win PC software collects both numerical and graphical results. As a result of that, these features provide an easier and more efficient analysis. After the test, DV-Win software generates a test report with a single click. Furthermore, a user can easily customize the test report and save it in different formats, such as XLS or PDF.Finally, the analysis of on-load tap changers is performed by the new method called dynamic resistance measurement (DRM). This is a non-intrusive method. Therefore, it allows detecting problems in on-load tap changers without disassembling them.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TD Series
Using the most advanced switch-mode technology available today, the RMO-TD series is ideal for winding resistance measurements of inductive objects. Transformer resistance meters and tap changer analyzers are perfect for testing:transformer windings (power transformers, distribution, autotransformers),all types of tap changers,generators,electrical motors,high-current busbar joints,cable splices,and welding joints.In addition, transformer demagnetization can also be done with all RMO-TD instruments.The RMO-TD series contains 3 models, with maximal test currents from 25 A (RMO25TD) to 60 A (RMO60TD).The three independent voltage sense channels enable testing of three windings in series. This enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.All RMO-TD transformer resistance meters have a built-in tap changer control unit. It enables remote control of on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, DV-Win software is included which can be programmed to do everything automatically – running winding resistance tests and changing OLTC tap positions.The DV-Win software also enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test.All results can be exported in the report format.
-
product
Battery Capacity Tester
BLU-A Series
The battery capacity test is performed to determine the health of a battery. DV Power’s battery load unit BLU-A is a portable, powerful, and lightweight solution for battery capacity measurement. It is applicable to any battery string such as lead-acid, Li-Ion, Ni-Cd, etc., with up to 500 V battery voltage. As a special feature, BLU100L model enables the capacity testing of a single Li-Ion cell.The capacity test is performed in an accurate and user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.Battery load unit BLU-A enables setting discharge currents up to 240 A, with a resolution 0,1 A. Furthermore, if higher currents are required, BLU-A units can be connected in parallel, or additional BXL load units can be used.The instrument offers the best power-to-weight ratio in the market. BLU-A models start from 12,8 kg / 28.2 lbs and deliver up to 28,4 kW of power.The user can select three discharge modes:Constant current,Constant power,Constant resistance.Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.The instrument monitors discharge parameters in real-time during the capacity test. A 4,3-inch touch screen display shows battery voltage, current, elapsed time, and capacity during the entire test. Also, BLU battery load unit can be used with DV-B Win software. As a result of that, a user can see a detailed numerical and graphical presentation of key parameters and can create reports in various formats.Testing with BLU-A doesn’t require a disconnection of the battery from the testing equipment.
-
product
Circuit Breaker Analyzers & Timers
CAT Handheld Series
When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.
-
product
Battery Capacity Testers|Discharge Testers
DV Power offers a wide range of battery capacity testers to meet specific customer needs. All of them are portable, powerful and most of all universal. Any battery string, such as lead-acid, lithium-ion, nickel-cadmium based and others, with voltages in the range of 0,9 – 800 V DC can be tested in an accurate, user-friendly way.The capacity test is carried out following the battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.BLU battery testers enable setting the discharge current up to 350 A, with 0,1 A resolution. If higher currents are required, several units can be connected in parallel, or BXL additional load units can be used. Discharge parameters can be monitored in real-time during the capacity test. Overall battery voltage, current, elapsed test time and capacity will be presented during the entire test on a touch screen display.
-
product
Turns Ratio Testers
TRT Standard Series
When it comes to choosing a transformer turns ratio tester, TRT Standard series offers some of the most advanced instruments with LCD display out in the market. Each model measures transformer excitation current and phase shift performs automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. Furthermore, they have a built-in true three-phase power source. Because of that, TRT Standard instruments can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 250 V AC, depending on the chosen model. High test voltage of 250 V AC provides more accurate turns ratio testing compared to other turns ratio testers on the market and extremely low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT Standard series consists of:TRT03 Models (TRT03A, TRT03B, TRT03C) – single-phase voltage up to 100 VTRT3x Models (TRT30A, TRT30B, TRT30C, TRT33A, TRT33B, TRT33C) – single and true three-phase voltage up to 100 VTRT63 Models (TRT63A, TRT63B, TRT63C) – single and true three-phase voltage up to 250 VMore about models differences can be found under the downloads tab, in brochures and comparison sheets.A user can create test templates using the DV Win software and store them in the PC’s memory for later use when in the field.TRT Standard series models have a built-in tap changer control unit. Consequently, it enables remote control of an on-load tap changer (OLTC) directly from the tester. In order to make the most out of this feature, the DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time.
-
product
Motor Winding Ohmmeter
RMO-M Series
The motor/generator winding resistance test is used to identify open windings, shorts between two windings, short to grounds, connection mistakes or shorted turns. This non-invasive test of winding resistance helps to pinpoint problems regarding windings in stator or rotor part of an electrical machine. Additionally, motor winding ohmmeter has the capability of performing heat run test which will show a change in windings resistance with an increase of temperature.The RMO-M series is designed as an ideal aid in preventive maintenance of electrical motors and generators. They are powerful (up to 100A of test current), portable (8 kg) and generate DC current which is completely ripple-free. This makes measurement very precise with 0,1% accuracy.Three voltage channels make measurement very easy since it is possible to obtain a value of all three winding resistances in one measurement
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
Coil Testers & Power Supplies
POB Series
Coil testers and power supply units, models POB30 and POB40 are ideal for commissioning and maintenance testing of circuit breakers. The station supply is not available. The POB series are power supply units implementing the latest power electronics technology. They are developed for use in switchyards, power and industrial environment. In addition to providing current and voltage for breaker testing, they can measure certain coil parameters.
-
product
Battery Capacity Tester
BLU-C Series
BLU-C is the latest solution from DV Power for conducting a comprehensive battery capacity test. This universal instrument is applicable to any battery string, such as lead-acid, Li-Ion, Ni-Cd, and others, with voltages up to 800 V DC.BLU-C tester simplifies battery testing in multiple ways. The instrument provides monitoring of discharge parameters (graphically and numerically) in real-time on a 7-inch touch screen display. The instrument also enables measurement and monitoring of cell parameters (voltage/intercell voltage/temperature), which makes it a complete stand-alone discharge test system.The capacity tester is compatible with DV-B Win software. Because of that, the user can view detailed numerical and graphical presentations of key parameters, and create reports in various formats.The capacity test is performed in a user-friendly way according to battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22 and other.The battery tester enables setting the discharge current up to 300 A, with 0,1 A resolution. If higher currents are required, BLU-C units can be connected in parallel, or BXL additional load units can be used.The user can select one of three discharge modes: Constant current, Constant power, Constant resistance. Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.Testing can be carried out without disconnecting the battery from the equipment it supplies.
-
product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
product
Battery Voltage Recorder
BVR Series
Battery voltage recorders from BVR series are designed to serve as a support tool for cell voltage measurement during battery capacity testing.During capacity testing, cell voltage, temperature, inter-cell connection voltage, and specific gravity should be measured in order to determine failling cells in the string that should be replaced.Furthermore, IEEE standards for stationary batteries applications stipulate periodical measurement of overall string voltage, as well as cell voltage and temperature.The BVR Series is the perfect tool for that purpose. All measurements are automatically saved in device’s internal memory. Additionally, DV-B Win software helps the user to download all measured results. Furthermore, the user can create test reports and export them to various formats.BVR series includes two models: BVR11 and BVR22. These are rechargeable handheld devices intended for performing monthly battery inspections and support tools during capacity testing. The list of the applications of these instruments includes:Efficient supplement to BLU series of battery load units during battery discharge testingMonthly inspections of large battery banksAmbient temperature measurementCurrent measurement using current clampsUSB and Bluetooth communication with PCSimultaneous string voltage and current measurement to analyze a discharge test processThe BVR22 model provides Bluetooth communication with an external density meter, for transferring electrolyte specific gravity and temperature readings.
-
product
Turns Ratio Testers
TRT Advanced Series
TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.
-
product
Transformer Turns Ratio Testers
Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.
-
product
Protective Bonding Testers
RMO-E Series
The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E